Memory module: faulty file system [0x0068001c, Electronic nameplate: checksum error [0x0068001d, 0x0068001f – Lenze E94AxPExxxx User Manual

Page 662: 0x0068001d, 0x0068001b, 0x0068001e, 0x0068001c, 14 diagnostics & fault analysis

Advertising
background image

14

Diagnostics & fault analysis

14.7

Error messages of the operating system

662

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Electronic nameplate: Communication error [0x0068001b]

Memory module: Faulty file system [0x0068001c]

Electronic nameplate: Checksum error [0x0068001d]

Firmware is incompatible with control card [0x0068001e]

Combination memory module/device not possible [0x0068001f]

Module ID (decimal)

Error ID (decimal)

104: Module identification

27

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Communication with the electronic nameplate is

interrupted, the data could not be read.

Check correct connection of the encoder cable.

Module ID (decimal)

Error ID (decimal)

104: Module identification

28

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Memory module is plugged in incorrectly or is defective.

• Plug in the memory module correctly.

• Exchange defective memory module.

Module ID (decimal)

Error ID (decimal)

104: Module identification

29

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The checksum of the electronic nameplate is defective.

Consultation with Lenze required.

Module ID (decimal)

Error ID (decimal)

104: Module identification

30

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Firmware is not compatible with the hardware.

Import the compatible firmware.

Module ID (decimal)

Error ID (decimal)

104: Module identification

31

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The memory module used is not supported by the

controller according to the license model.

Plug in supported module and switch the mains.

• The 9400 PLC supports the MM340 and MM440

memory modules (licence: Motion Control PLC).

Advertising