12 basic drive functions – Lenze E94AxPExxxx User Manual
Page 538
Advertising
![background image](/manuals/566084/538/background.png)
12
Basic drive functions
12.11
Limiter
538
Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
LIM_bLimitSwitchPositive
| BOOL
Input for positive travel range limit switch
TRUE Limit switch is activated.
LIM_bLimitSwitchNegative
| BOOL
Input for negative travel range limit switch
TRUE Limit switch is activated.
LIM_bActivateLimitedSpeed
1
| BOOL
Request limited speed 1
• If a setpoint follower is active, no limitation takes place, but an exceeding of the
limit values is displayed via the output LIM_dnState.
TRUE Request limited speed 1.
Identifier
DIS code | data type
Information/possible settings