Code refresh [0x00690000, Internal error (memory area - logbook) [0x00690001, Internal error (lds instance data) [0x00690002 – Lenze E94AxPExxxx User Manual

Page 664: 0x00690000, 0x00690002, 0x00690001, 0x00680024, 14 diagnostics & fault analysis

Advertising
background image

14

Diagnostics & fault analysis

14.7

Error messages of the operating system

664

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Real-time clock: Battery empty, time lost [0x00680024]

Code refresh [0x00690000]

Internal error (memory area - logbook) [0x00690001]

Internal error (LDS instance data) [0x00690002]

Module ID (decimal)

Error ID (decimal)

104: Module identification

36

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The battery integrated in the clock in the MM440

memory module is empty. The clock has been reset to its

initial value (01.01.1970 - 00:00:00 o'clock).

• If the memory module is used for the first time,

restart the controller to initialise the memory

module.

• If the problem occurs again, replace the memory

module.

Module ID (decimal)

Error ID (decimal)

105: Error check of the program memory during runtime

0

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Serious device error or component failure.

Switch the controller off and then on again.

• Please contact Lenze if the problem occurs again.

Module ID (decimal)

Error ID (decimal)

105: Error check of the program memory during runtime

1

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Serious device error or component failure.

Switch the controller off and then on again.

• Please contact Lenze if the problem occurs again.

Module ID (decimal)

Error ID (decimal)

105: Error check of the program memory during runtime

2

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Serious device error or component failure.

Switch the controller off and then on again.

• Please contact Lenze if the problem occurs again.