37 activate parameter set 1, Activate parameter set 1, 5drive interface – Lenze E94AxPExxxx User Manual

Page 134

Advertising
background image

5

Drive interface

5.2

Device commands

134

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2.37

Activate parameter set 1 ... 4

In addition to the start parameters, up to four further parameter sets can be stored in the memory

module for each application. Like this you can for instance define different controller settings for an

application, which are then simply activated via device command, if required.
The following device commands are used to archive the current parameter settings of the controller

for the active application in the memory module as parameter set 1 ... 4:

C00002

= "301: Archive parameter set 1"

C00002

= "302: Archive parameter set 2"

C00002

= "303: Archive parameter set 3"

C00002

= "304: Archive parameter set 4"

[5-21] Example: "Archive parameter set 1" function

• Previously archived parameter settings will be overwritten with the current parameter settings!

* In this example, application 1 is the active application

PS 4

PS 3

PS 2

Application 2

PS 1

PS

PS 4

PS 3

PS 2

Memory module MM

PS

9400

PS

RAM

Firmware

Application 1*

Application 1*

PS

PS 1

Advertising