Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

819

15

Parameter reference

15.2

Parameter list | C00573

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00573

C00574

C00576

C00577

Parameter | Name:

C00573 | Resp. to overload brake trans.

Data type: UNSIGNED_32

Index: 24002

d

= 5DC2

h

Response to activation of brake chopper monitoring

Braking operation

Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00574 | Resp. to brake resist. overtemp.

Data type: UNSIGNED_32

Index: 24001

d

= 5DC1

h

Response to activation of brake resistor monitoring

Braking operation

Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00576 | Speed monitoring tolerance

Data type: UNSIGNED_32

Index: 23999

d

= 5DBF

h

Monitoring window for speed control error in [%] of nmax
Setting range

(min. value | unit | max. value)

Lenze setting

0

%

100 100 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00577 | Field weakening controller gain

Data type: UNSIGNED_32

Index: 23998

d

= 5DBE

h

At "0" the P component is deactivated, a pure I-controller is used.
Setting range

(min. value | unit | max. value)

Lenze setting

0.000

Vs/V

2147483.647 0.000 Vs/V

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000