Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

81

5

Drive interface

5.1

Machine parameters

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.1.1

Mains voltage

Via the Mains voltage list field (

C00173

) the mains voltage for the controller is set.

• If you set a mains voltage with an adjustable threshold for undervoltage ("LU adjustable"), this

undervoltage threshold can be set in the Undervoltage threshold (LU) input field (

C00174

).

• In the Resp. to DC-bus overvoltage list field (

C00600

) you can select the response that is to be

effected when a DC-bus overvoltage occurs.

Tip!
In the chapter "Rated data" of the hardware manual the device types and their permissible

device utilisation at a certain mains voltage and switching frequency are specified.

See also:

Monitoring of the device utilisation

( 156)

Note!

Changing the setting in

C00173

also affects the permissible device utilisation!