C00954 | vfc: activat. interpol. point n, C00955 | vfc: vmax reduction, C00957 | vfc: vvc current setpoint – Lenze E94AxPExxxx User Manual

Page 847: C00958 | vfc: vvc gain, C00954/1, C00957, C00958, C00954, 15 parameter reference

Advertising
background image

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

847

15

Parameter reference

15.2

Parameter list | C00954

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00954

C00955

C00957

C00958

Parameter | Name:

C00954 | VFC: Activat. interpol. point n

Data type: UNSIGNED_32

Index: 23621

d

= 5C45

h

V/f control

Selection list

0 Off
1 On

Subcodes

Lenze setting

Info

C00954/1

1: On

C00954/2

1: On

C00954/3

1: On

C00954/4

1: On

C00954/5

1: On

C00954/6

1: On

C00954/7

1: On

C00954/8

1: On

C00954/9

1: On

C00954/10

1: On

C00954/11

1: On

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00955 | VFC: Vmax reduction

Data type: UNSIGNED_32

Index: 23620

d

= 5C44

h

V/f control

Setting range

(min. value | unit | max. value)

Lenze setting

0

V

500 0 V

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00957 | VFC: VVC current setpoint

Data type: INTEGER_32

Index: 23618

d

= 5C42

h

V/f control

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

A

1500.00 0.00 A

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C00958 | VFC: VVC gain

Data type: UNSIGNED_32

Index: 23617

d

= 5C41

h

V/f control

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

V/A

750.00 0.00 V/A

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100