915

15

Parameter reference

15.2

Parameter list | C02772

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02772

C02773

C02774

Parameter | Name:

C02772 | Starting angle

Data type: INTEGER_32

Index: 21803

d

= 552B

h

From software version V2.0

Basic function "

Manual jog open loop

"

Setting range

(min. value | unit | max. value)

-180.0

°

180.0

Subcodes

Lenze setting

Info

C02772/1

0.0 °

Startangle 1

C02772/2

0.0 °

Startangle 2

C02772/3

0.0 °

Startangle 3

C02772/4

0.0 °

Startangle 4

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Parameter | Name:

C02773 | Current

Data type: INTEGER_32

Index: 21802

d

= 552A

h

From software version V2.0

Basic function "

Manual jog open loop

"

Setting range

(min. value | unit | max. value)

0.00

%

100.00

Subcodes

Lenze setting

Info

C02773/1

10.00 %

Current 1

C02773/2

10.00 %

Current 2

C02773/3

10.00 %

Current 3

C02773/4

10.00 %

Current 4

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 100

Parameter | Name:

C02774 | Acceleration time

Data type: INTEGER_32

Index: 21801

d

= 5529

h

From software version V2.0

Basic function "

Manual jog open loop

"

Setting range

(min. value | unit | max. value)

0.001

s

2147483.647

Subcodes

Lenze setting

Info

C02774/1

1.000 s

Acceleration time 1

C02774/2

1.000 s

Acceleration time 2

C02774/3

1.000 s

Acceleration time 3

C02774/4

1.000 s

Acceleration time 4

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1000