2 load start parameters, Load start parameters, 5drive interface – Lenze E94AxPExxxx User Manual

Page 95

Advertising
background image

Lenze · 9400 Servo PLC· Reference manual · DMS 4.0 EN · 11/2013 · TD05/06

95

5

Drive interface

5.2

Device commands

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2.2

Load start parameters

Via

C00002

= "1: Load start parameters" the start parameters of the active application can be

reloaded from the memory module to the controller:

[5-13] "Load start parameters" function

• Only possible when the application has stopped and the controller is inhibited.
• All parameter changes made since the last saving of the parameter set will get lost!
• This device command only affects the settings of the operating system, application and module

parameters, the active application remains unchanged.

Possible status displays for this device command

Related device commands

Save start parameters

( 99)

Load Lenze setting

( 94)

* In this example, application 1 is the active application

PS

9400

RAM

Firmware

Application 1*

PS

Application 3

PS

Application 2

PS

Memory module MM

PS

Application 1*

Status (

C00003

)

Meaning

99586 Device command in process

65536 Device command executed successfully

65537 General error
99371 Fault while reading the parameter set partition
99374 No memory module available

104960 CAN fault

... ...

105215 CAN fault