4.3 The Drive and Programming Modes

100

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

Setup Group Parameters

Table 4.4

lists parameters available by default in the Setup Group.

If a parameter that needs to be edited is not displayed in the Setup Group, access the parameter through the Programming
Mode.

Table 4.4 Setup Group Parameters

Note: Parameter availability depends on the control mode set in A1-02; some parameters listed above may not be accessible in all

control modes.

Switching Between LOCAL and REMOTE

LOCAL mode is when the drive is set to accept the Up/Down command from the digital operator keypad. REMOTE
mode is when the drive is set to accept the Up/Down command from an external device (via the input terminals or serial
communications, etc.).

Switch the operation between LOCAL and REMOTE using the LO/RE key on the digital operator or via a digital input.
This key is disabled with default settings, but can be enabled by setting parameter o2-01 to 1.

Note: 1. After selecting LOCAL, the LO/RE light will remain lit.

2. The drive will not allow the user to switch between LOCAL and REMOTE during run.

Using the LO/RE Key on the Digital Operator

Parameter

Name

Parameter

Name

A1-02

Control Method Selection

E1-01

Input Voltage Setting

b1-01

Speed Reference Selection

E1-04

Maximum Output Frequency

C1-01

Acceleration Ramp 1

E1-05

Maximum Voltage

C1-02

Deceleration Ramp 1

E1-06

Base Frequency

d1-01

Speed Reference 1

E1-09

Minimum Output Frequency

d1-02

Speed Reference 2

E1-13

Base Voltage

d1-03

Speed Reference 3

E2-01

Motor Rated Current

d1-04

Speed Reference 4

E2-11

Motor Rated Output

d1-26

Leveling Speed

L1-01

Motor Overload Protection Selection

Step

Display/Result

1.

Turn on the power to the drive. The initial display appears.

2.

Press

. The LO/RE light will light up. The drive is now in LOCAL.

To set the drive for REMOTE operation, press

again.

- MODE -

U1-01= 0.00%

U1-02= 0.00%
U1-03= 0.00A

DRV

Speed Ref(A1/A2)

Rdy

RSEQ
RREF

FWD

YEA_

com-

LO
RE

F2

F1

ESC

RUN

STOP

ENTER

RESET

ALM

DIGITAL OPERATOR JVOP-180

- MODE -

U1-01= 0.00%

U1-02= 0.00%
U1-03= 0.00A

DRV

Speed Ref (OPR)

Rdy

LSEQ
LREF

FWD

YEA

_ c o

mm