4.3 The Drive and Programming Modes

100

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

■

Setup Group Parameters

Table 4.4

lists parameters available by default in the Setup Group.

If a parameter that needs to be edited is not displayed in the Setup Group, access the parameter through the Programming
Mode.

Table 4.4 Setup Group Parameters

Note: Parameter availability depends on the control mode set in A1-02; some parameters listed above may not be accessible in all

control modes.

◆ Switching Between LOCAL and REMOTE

LOCAL mode is when the drive is set to accept the Up/Down command from the digital operator keypad. REMOTE
mode is when the drive is set to accept the Up/Down command from an external device (via the input terminals or serial
communications, etc.).

Switch the operation between LOCAL and REMOTE using the LO/RE key on the digital operator or via a digital input.
This key is disabled with default settings, but can be enabled by setting parameter o2-01 to 1.

Note: 1. After selecting LOCAL, the LO/RE light will remain lit.

2. The drive will not allow the user to switch between LOCAL and REMOTE during run.

■

Using the LO/RE Key on the Digital Operator

Parameter

Name

Parameter

Name

A1-02

Control Method Selection

E1-01

Input Voltage Setting

b1-01

Speed Reference Selection

E1-04

Maximum Output Frequency

C1-01

Acceleration Ramp 1

E1-05

Maximum Voltage

C1-02

Deceleration Ramp 1

E1-06

Base Frequency

d1-01

Speed Reference 1

E1-09

Minimum Output Frequency

d1-02

Speed Reference 2

E1-13

Base Voltage

d1-03

Speed Reference 3

E2-01

Motor Rated Current

d1-04

Speed Reference 4

E2-11

Motor Rated Output

d1-26

Leveling Speed

L1-01

Motor Overload Protection Selection

Step

Display/Result

1.

Turn on the power to the drive. The initial display appears.

2.

Press

. The LO/RE light will light up. The drive is now in LOCAL.

To set the drive for REMOTE operation, press

again.

- MODE -

U1-01= 0.00%

U1-02= 0.00%
U1-03= 0.00A

DRV

Speed Ref(A1/A2)

Rdy

RSEQ
RREF

FWD

YEA_

com-

LO
RE

F2

F1

ESC

RUN

STOP

ENTER

RESET

ALM

DIGITAL OPERATOR JVOP-180

- MODE -

U1-01= 0.00%

U1-02= 0.00%
U1-03= 0.00A

DRV

Speed Ref (OPR)

Rdy

LSEQ
LREF

FWD

YEA

_ c o

mm