C.9 MEMOBUS/Modbus Data Table

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

431

MEMOBUS

/Mo

dbu

s

C

o

m

m

u

ni

ca

ti

on

s

C

C.9 MEMOBUS/Modbus Data Table

Table below lists all MEMOBUS/Modbus data. There are three types of data: command data, monitor data, and broadcast
data.

Command Data

It is possible to both read and write command data.

Note: Bits that are not used should be set to 0. Refrain from writing to reserved registers.

Register No.

Contents

0000H

<1> To enable torque compensation function by serial communications, set H3-10 to 14.

Reserved

0001H

Operation Commands and Multi-function Inputs
bit 0

Up command

bit 1

Down command

bit 2

External Fault (EF0)

bit 3

Fault Reset

bit 4

ComRef
Note: When the bit at ComCtrl is turned on, commands from MEMOBUS communications take control of the operation. However,
when a communications option card is connected, that option card is given priority.

bit 5

ComCtrl

bit 6

Multi-Function Input 3

bit 7

Multi-Function Input 4

bit 8

Multi-Function Input 5

bit 9

Multi-Function Input 6

bit A

Multi-Function Input 7

bit B

Multi-Function Input 8

bit C to F

Reserved

0002H

Speed Reference

Units are determined by parameter o1-03.

0003H

Reserved

0004H

Torque Limit, 0.1% units, signed

0005H

Torque Compensation, 0.1% units, signed

0006H

Reserved

0007H

Analog Output Terminal FM Setting (10 V/4000 H)

0008H

Analog Output Terminal AM Setting (10 V/4000 H)

0009H

Settings for Multi-Function Digital Outputs
bit 0

Multi-Function Relay Output 1 (terminal M1-M2)

bit 1

Multi-Function Relay Output 2 (terminal M3-M4)

bit 2

Multi-Function Relay Output 3 (terminal M5-M6)

bit 3

Multi-Function Photocoupler Output 1 (terminal P1-C1)

bit 4

Multi-Function Photocoupler Output 2 (terminal P2-C2)

bit 5

Reserved

bit 6

Enables the function in bit 7

bit 7

Fault Contact Output (terminal MA/MB-MC)

bit 8 to F

Reserved

000AH to 000EH

Reserved

000FH

Control Selection Setting
bit 0, 1

Reserved

bit 2

Torque limit input (enables the setting from MEMOBUS/Modbus)

bit 3

Torque compensation input (enables the setting from MEMOBUS/Modbus)

bit 4 to B

Reserved

bit C

Enable Terminal S5 Input for Broadcast Data

bit D

Enable Terminal S6 Input for Broadcast Data

bit E

Enable Terminal S7 Input for Broadcast Data

bit F

Enable Terminal S8 Input for Broadcast Data

0010H to 001AH

Reserved

001BH

Analog Monitor Option AO-A3 Analog Output 1 (10 V/4000 H)

001CH

Analog Monitor Option AO-A3 Analog Output 2 (10 V/4000 H)

001DH

Digital Output Option DO-A3 Output (Binary)

001EH to 001FH

Reserved

Advertising