B.3 Parameter Table

394

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

n6: Online Tuning

n8: PM Motor Control Tuning

No. (Addr.)

Name

Description

Setting

Page

n6-01

(570H)

Online Tuning Selection

0: Disabled
1: Line-to-line resistance tuning
2: Voltage correction.

Default: 2

Min: 0
Max: 2

235

n6-05

(5C7H)

Online Tuning Gain

Decrease this setting for motors with a relatively large rotor time constant.
If overload occurs, increase this setting slowly in increments of 0.1.

Default: 1.0

Min: 0.1
Max: 50.0

236

No. (Addr.)

Name

Description

Setting

Page

n8-01

(540H)

<9> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.

Initial Polarity Estimation Current

Sets the current used for initial rotor position estimation as a percentage of the motor rated
current (E5-03). If the motor nameplate lists an “Si” value, that value should be entered here.

Default: 50%

Min: 0%
Max: 100%

236

n8-02

(541H)

Pole Attraction Current

Sets the current during initial polar attraction as a percentage of the motor rated current. Enter a
high value when attempting to increase starting torque.

Default: 80%

Min: 0%
Max: 150%

236

n8-29

(55CH)

q-Axis Current Control Gain
during Normal Operation

Sets the q axis proportional gain for the normal control range.

Default: 1000 rad/s
Min: 0 rad/s
Max: 2000 rad/s

238

n8-30

(55DH)

q-Axis Current Control Integral
Time during Normal Operation

Sets the q axis integral time for the normal control range.

Default: 10.0 ms
Min: 0.0 ms
Max: 100.0 ms

238

n8-32

(55FH)

d-Axis Current Control Gain
during Normal Operation

Sets the d axis proportional gain for the normal control range.

Default: 1000 rad/s
Min: 0 rad/s
Max: 2000 rad/s

238

n8-33

(560H)

d-Axis Current Control Integral
Time during Normal Operation

Sets the d axis integral time for the normal control range.

Default: 10.0 ms
Min: 0.0 ms
Max: 100.0 ms

238

n8-35

(562H)

Initial Rotor Position Detection
Selection

1: High frequency injection
2: Pulse injection

Default: 1

Min: 1
Max: 2

236

n8-36

(563H)

High Frequency Injection Level

Sets the frequency in Hz for the superimposed signal used for superimposed harmonics.

Default: 500 Hz
Min: 25 Hz
Max: 1000 Hz

237

n8-37

(564H)

High Frequency Injection
Amplitude

Sets the amplitude for superimposed harmonics according to the voltage class of the motor.
Adjust this value when there is too much or too little current as a result of the settings assigned
to motor parameters.

Default: 20.0%
Min: 0.0%
Max: 99.9%

237

n8-62

(57DH)

Output Voltage Limit

Prevents output voltage saturation. Should be set just below the voltage provided by the input
power supply.

Default: 200.0 V

<9>

Min: 0.0 V
Max: 230.0 V

<9>

238

n8-81

(2D0H)

High Frequency Injection during
Rescue Operation

Sets the frequency used for Polar Detection Method 1 during Rescue Operation.

Default: 90 Hz
Min: 25 Hz
Max: 1000 Hz

237

n8-82

(2D1H)

High Frequency Injection
Amplitude during Rescue
Operation

Sets the amplitude for High Frequency Injection during Rescue Operation as a percentage of the
voltage (200 V or 400 V).

Default: 15.0%
Min: 0.1%
Max: 99.9%

237

n8-84

(2D3H)

Polarity Detection Current

Sets the current level (E5-03) as a percentage for detecting polarity during Initial Polarity
Estimation.

Default: 100%
Min: 0%
Max: 150%

237

n8-86

(2D5H)

Magnet Pole Search Error
Detection Selection

0: Disabled
1: Enabled

Default: 0
Min: 0
Max: 1

237

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

Advertising