n: Advanced Performance Set-Up

The n parameters are used to adjust more advanced performance characteristics such as speed feedback detection, Online
Tuning for motor line-to-line resistance, and PM motor control tuning.

n1: Hunting Prevention

n2: Speed Feedback Detection Control (AFR) Tuning

n5: Inertia Compensation

L8-99

(B98H)

Current Monitoring Level

Sets the current monitoring level as a percentage of the drive's rated current. Sets the level of
current used to monitor the status of the current (H2-††. = 5C) when the Current Monitoring
Selection (L8-89) is enabled and set to 1.

Default: 10.0 %
Min: 0.0 %
Max: 50.0 %

231

<1> Default setting is determined by the drive model (o2-04).

<3> Setting 3 available in V/f and OLV control only.

<4> Parameter setting value is not reset to the default value when the drive is initialized.

No. (Addr.)

Name

Description

Setting

Page

n1-08

(1105H)

Leakage Current Vibration Control
Selection

0: Method 1
1: Method 2
Parameter does not normally require adjustment.

Default: 0

Min: 0
Max: 1

232

No. (Addr.)

Name

Description

Setting

Page

n2-01

(584H)

Speed Feedback Detection Control
(AFR) Gain

Sets the internal speed feedback detection control gain in the automatic frequency regulator
(AFR).
If hunting occurs, increase the set value. If response is low, decrease the set value.

Default: 1.00

Min: 0.00
Max: 10.00

232

n2-02

(585H)

Speed Feedback Detection Control
(AFR) Time Constant 1

Sets the time constant used for speed feedback detection control (AFR).

Default: 50 ms

Min: 0 ms
Max: 2000 ms

232

n2-03

(586H)

Speed Feedback Detection Control
(AFR) Time Constant 2

Sets the AFR time constant to be used during regen.

Default: 750 ms

Min: 0 ms
Max: 2000 ms

No. (Addr.)

Name

Description

Setting

Page

n5-01

(5B0H)

<4> Default setting value is dependent on the drive model (o2-04).

Inertia Compensation Selection

0: Disabled
1: Enabled

Default: 0

Min: 0
Max: 1

233

n5-02

(5B1H)

Motor Acceleration Time

Sets the time required to accelerate the motor at 100% torque from 0 to the nominal speed.

Default:

<4>

Min: 0.001 s
Max: 10.000 s

233

n5-03

(5B2H)

Inertia Compensation Gain

Sets the ratio between motor and load inertia. Lower this setting if overshoot occurs at the end
of acceleration.

Default: 1.00

Min: 0.00
Max: 100.00

234

n5-07

(170H)

Speed Feedback Compensation
Selection

0: Disabled
1: Enabled
2: Test Mode

Default: 1
Min: 0
Max: 2

235

n5-08

(171H)

Speed Feedback Compensation
Gain (P)

Sets the proportional gain for the Speed Feedback Compensation.

Default: 12.00
Min: 0.00
Max: 300.00

235

No. (Addr.)

Name

Description

Setting

Page

All Modes

common

_

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

Advertising