6.8 Diagnosing and Resetting Faults

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

305

T

ro

ubles

hoo

ting

6

Fault Reset Methods

When a fault occurs, the cause of the fault must be removed and the drive must be restarted. The table below lists the
different ways to restart the drive.

Note: If the Up/Down command is present, the drive will disregard any attempts to reset the fault. Remove the Up/Down command

before attempting to clear a fault situation.

After the Fault Occurs

Procedure

Fix the cause of the fault, restart the drive, and
reset the fault

Press

on the digital operator when error code is

displayed.

Resetting via Fault Reset Digital Input S4

Close then open the fault signal digital input via terminal S4.
S4 is set for “Fault Reset” as default (H1-04 = 14).

If the above methods do not reset the fault, turn off the drive main power supply. Reapply power after the digital
operator display is out.

LO
RE

F2

F1

ESC

RUN

STOP

ENTER

RESET

ALARM

DIGITAL OPERATOR JVOP-180

RESET

- MODE -

oC

Overcurrent

DRV

FWD

RESET

YEA

Fault Reset Switch

Drive

S4 Fault Reset Digital Input

SC Digital Input Common

ON

OFF

2