Parameter settings during pm motor auto-tuning: t2, T1-10: motor rated slip, T2-01: pm auto-tuning mode selection – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 117: T2-04: pm motor rated power, T2-05: pm motor rated voltage, T2-06: pm motor rated current, 5 auto-tuning, Specifies the pm motor rated power in kilowatts, Sets the pm motor rated voltage, Enter the pm motor rated current in amps

Advertising
background image

4.5 Auto-Tuning

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

117

St

ar

t-

U

p

Pr

og

ra

m

m

in

g

&

Op

er

at

io

n

4

T1-10: Motor Rated Slip

Sets the rated slip for the motor.

The default setting displayed is the motor rated slip for a Yaskawa motor calculated from the output power set in T1-02.
Enter the data listed on the motor test report.

Parameter Settings during PM Motor Auto-Tuning: T2

The T2-†† parameters are used to set the Auto-Tuning input data for PM motor tuning.

T2-01: PM Auto-Tuning Mode Selection

Selects the type of Auto-Tuning to be performed.

Refer to Auto-Tuning for Permanent Magnet Motors on page 110

for

details on different types of Auto-Tuning.

Setting 0: Motor Data Input
Setting 1: PM Stationary Auto-Tuning
Setting 2: PM Stationary Stator Resistance Auto-Tuning
Setting 3: Initial Magnet Pole Search Parameters Auto-Tuning
Setting 4: Stationary PG Encoder Offset Auto-Tuning
Setting 10: Rotational PG Encoder Offset Auto-Tuning
Setting 11: Rotational Back EMF Constant Auto-Tuning
Setting 12: Auto-Tuning of PG-E3 Encoder Characteristics

T2-04: PM Motor Rated Power

Specifies the PM motor rated power in kilowatts.

T2-05: PM Motor Rated Voltage

Sets the PM motor rated voltage.

T2-06: PM Motor Rated Current

Enter the PM motor rated current in amps.

No.

Parameter Name

Setting Range

Default

T1-10

Motor Rated Slip

0.00 to 20.00 Hz

No.

<1> Auto-Tuning of PG-E3 encoder characteristics requires a PG-E3 option with software version 1102 or later. To identify the PG-E3 software

version, refer to the PG-E3 labeling on the option in the field designated “C/N” (S + four-digit number).

Parameter Name

Setting Range

Default

T2-01

PM Auto-Tuning Mode Selection

0 to 4, 10 to 12

<1>

0

No.

Parameter Name

Setting Range

Default

T2-04

PM Motor Rated Power

0.00 to 650.00 kW

Depending on o2-04

No.

Parameter Name

Setting Range

Default

<1> Values shown are specific to 200 V class drives. Double value for 400 V class drives.

T2-05

PM Motor Rated Voltage

0.0 to 255.0 V

<1>

200.0 V

<1>

No.

Parameter Name

Setting Range

Default

T2-06

PM Motor Rated Current

10% to 200% of the drive rated

current.

Depending on o2-04

Advertising