B.3 Parameter Table

376

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

E2: Motor Parameters

E1-04

(303H)

Maximum Output Frequency

To set linear V/f characteristics, set the same values for E1-07 and E1-09. In this case, the
setting for E1-08 will be disregarded. Ensure that the five frequencies are set according to these
rules:
E1-09

≤ E1-07 < E1-06 ≤ Ε1−11 ≤ E1-04

Note that if E1-11 = 0, then both E1-11 and E1-12 are disabled, and the above conditions do not
apply.

Note: Some parameters may not be available depending on the control mode.

• E1-07, E1-08 and E-10 are available only in the V/f control and Open Loop Vector control

modes.

• E1-11, E1-12 and E-13 are available only in the V/f control and Closed Loop Vector control

modes.

Default:

<5>

Min:

<23>

Max: 200.0 Hz

178

E1-05

(304H)

Maximum Voltage

Default: 230.0 V

<9>

Min: 0.0 V
Max: 255.0 V

<9>

E1-06

(305H)

Base Frequency

Default:

<5>

Min: 0.0 Hz
Max: 200.0 Hz

E1-07

(306H)

Middle Output Frequency

Default: 3.0 Hz
Min: 0.0 Hz
Max: 200.0 Hz

E1-08

(307H)

Middle Output Frequency Voltage

Default:

<2> <9>

Min: 0.0 V
Max: 255.0 V

<9>

E1-09

(308H)

Minimum Output Frequency

Default:

<5>

Min: 0.0 Hz
Max: 200.0 Hz

E1-10

(309H)

Minimum Output Frequency
Voltage

Default:

<2> <9>

Min: 0.0 V
Max: 255.0 V

<9>

E1-11

(30AH)

<11>

Middle Output Frequency 2

Default: 0.0 Hz

Min: 0.0 Hz
Max: 120.0 Hz

E1-12

(30BH)

<11>

Middle Output Frequency Voltage 2

Default: 0.0 V

<9>

Min: 0.0 V
Max: 255.0 V

<9>

E1-13

(30CH)

<13>

Base Voltage

Default: 0.0 V

<9>

Min: 0.0 V
Max: 255.0 V

<9>

<2> Default setting is dependent on the control mode (A1-02) and the drive model (o2-04).

<5> Default setting is determined by the control mode (A1-02).

<9> Values shown here are for 200 V class drives. The default is 400 V when using a 400 V class drive.

<11> Parameter is ignored when E1-11 and E1-12 are set to 0.0.

<13> When E1-13 (Base Voltage) is set to 0.0, output voltage is controlled with E1-05 (Maximum Voltage) = E1-13. When Auto-Tuning is

performed, E1-05 and E1-13 are automatically set to the same value.

<23> Setting range depends on the type of motor being used. CLV allows a setting range of 10.0 to 120.0 Hz, while CLV/PM allows a setting range

of 4.0 to 120.0 Hz.

No.(Addr.)

Name

Description

Setting

Page

E2-01

(30EH)

Motor Rated Current

Sets the motor nameplate full load current in Amps. Automatically set during Auto-Tuning.

Default:

<4>

Min: 10% of drive rated
current
Max: 200% of drive
rated current

<10>

179

E2-02

(30FH)

Motor Rated Slip

Sets the motor rated slip. Automatically set during Auto-Tuning.

Default:

<4>

Min: 0.00 Hz
Max: 20.00 Hz

179

E2-03

(310H)

Motor No-Load Current

Sets the no-load current for the motor. Automatically set during Auto-Tuning.

Default:

<4>

Min: 0 A
Max: E2-01

<10>

179

E2-04

(311H)

Number of Motor Poles

Sets the number of motor poles. Automatically set during Auto-Tuning.

Default: 4

Min: 2
Max: 48

180

E2-05

(312H)

Motor Line-to-Line Resistance

Sets the phase-to-phase motor resistance. Automatically set during Auto-Tuning.

Default:

<4>

Min: 0.000

Ω

Max: 65.000

Ω

180

E2-06

(313H)

Motor Leakage Inductance

Sets the voltage drop due to motor leakage inductance as a percentage of motor rated voltage.
Automatically set during Auto-Tuning.

Default:

<4>

Min: 0.0%
Max: 40.0%

180

E2-07

(314H)

Motor Iron-Core Saturation
Coefficient 1

Sets the motor iron saturation coefficient at 50% of magnetic flux. Automatically set during
Auto-Tuning.

Default: 0.50

Min: 0.00
Max: 0.50

180

E2-08

(315H)

Motor Iron-Core Saturation
Coefficient 2

Sets the motor iron saturation coefficient at 75% of magnetic flux. Automatically set during
Auto-Tuning.

Default: 0.75

Min: E2-07
Max: 0.75

180

No.(Addr.)

Name

Description

Setting

Page

All Modes

common

_

Output Voltage (V)

Frequency (Hz)

E1-05
E1-12

E1-13

E1-08

E1-10

E1-09

E1-07 E1-06 E1-11 E1-04

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

CLV

CLV/PM

V/f

OLV

common

_

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

Advertising