5.7 H: Terminal Functions

200

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

Setting 3: User-set speed agree 1 (f

ref

/f

set

Agree 1)

Closes whenever the actual output speed or motor speed (CLV, CLV/PM) and the speed reference are within the speed
agree width (L4-02) of the programmed speed agree level (L4-01).

Note: Detection works in both forward and reverse. The value of L4-01 is used as the detection level for both directions.

Figure 5.20

Figure 5.20 User Set Speed Agree 1 Time Chart

Refer to L4-01, L4-02: Speed Agreement Detection Level and Detection Width on page 219

for more instructions.

Setting 4: Speed Detection 1

Output opens when the output speed (CLV, CLV/PM) rises above the detection level set in L4-01 plus the detection width
set in L4-02. The terminal remains open until the output speed falls below the level set in L4-01.

Note: Detection works in both forward and reverse. The value of L4-01 is used as the detection level for both directions.

Figure 5.21

Figure 5.21 Speed Detection 1 Time Chart

Refer to L4-01, L4-02: Speed Agreement Detection Level and Detection Width on page 219

for more details.

Setting 5: Speed Detection 2

Output closes whenever the output speed or motor speed (CLV, CLV/PM) is above the detection level set in L4-01. The
terminal remains closed until the output speed or motor speed falls below L4-01 minus the setting of L4-02.

Note: Detection works in both forward and reverse. The value of L4-01 is used as the detection level for both directions.

Status

Description

Open

Output speed or motor speed and the speed reference are not both within the range of L4-01 ±L4-02.

Closed

Output speed or motor speed and the speed reference are both within the range of L4-01 ±L4-02.

Status

Description

Open

Output speed or motor speed exceeded L4-01 + L4-02.

Closed

Output speed or motor speed is below L4-01 or has not exceeded L4-01 + L4-02.

Status

Description

Open

Output speed or motor speed is below L4-01 minus L4-02 or has not exceeded L4-01.

Closed

Output speed or motor speed exceeded L4-01.

User Set

Speed Agree 1

OFF

ON

Speed
reference

OFF

ON

Speed
reference

Output
speed

L4-01

+/- L4-02

L4-01

+/- L4-02

Output speed

or motor speed

common_TMo

L4-02

Speed
detection 1

ON

OFF

L4-02

L4-01

L4-01

Output speed

or motor speed

common_