C.5 Drive Operations by MEMOBUS/Modbus

The drive operations that can be performed by MEMOBUS/Modbus communication depend on drive parameter settings.
This section explains the functions that can be used and related parameter settings.

Observing the Drive Operation

A PLC can perform the following actions with MEMOBUS/Modbus communications at any time regardless of parameter
settings (except H5-††).

• Observe drive status and drive control terminal status from a PLC.
• Read and write parameters.
• Set and reset faults.
• Set multi-function inputs.

Note: Input settings from the input terminals S† and from MEMOBUS/Modbus communications are both linked by a logical OR

operation.

Controlling the Drive

Select an external reference and adjust the parameters in

Table C.1

accordingly to start and stop the drive or set the

frequency reference using MEMOBUS/Modbus communications.

Table C.1 Setting Parameters for Drive Control from MEMOBUS/Modbus

Refer to b1-01: Speed Reference Selection on page 156

and

Refer to b1-02: Up/Down Command Selection on page 157

for details on operation mode parameter selections.

Reference Source

Parameter

Name

Required Setting

External Reference

b1-01

Speed Reference Selection

2

b1-02

Up/Down command Selection

2