4 option card installation, Pg encoder cables for pg-b3 option – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 343

Advertising
background image

8.4 Option Card Installation

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

343

Per

iphe

ra

l De

vi

ce

s &

Optio

n

s

8

PG Encoder Cables for PG-B3 Option

Yaskawa recommends using a LMA-……B-S185Y (complementary output) for cables running between the PG-B3
Option and the PG as show in

Figure 8.10

.

For instructions on wiring the terminal block, refer to

Table 8.9

.

Figure 8.8

Figure 8.10 Wiring PG Encoder Cable

Table 8.3 Connecting the PG Encoder Cable Specification

Table 8.4 PG Encoder Cable Types

6.

For the PG-X3 Option, set the voltage for the PG encoder power supply using jumper CN3 located on the option.
Position the jumper as shown in

Table 8.5

to select the voltage level.

NOTICE: The positioning of jumper CN3 selects the PG encoder power supply voltage (5.5 V or 12 V). Select the voltage level for the

PG encoder connected to the option and motor. If the wrong voltage is selected, the PG encoder may not operate properly or may

become damaged as a result.

Table 8.5 Setting the PG Encoder Power Supply Voltage (IP) with Jumper CN3

Option Terminal

PG Encoder Cable

Wire

Color

Pin

IP

1

Blue

C

IG

2

White

H

A+

3

Yellow

B

A–

4

White

G

B+

5

Green

A

B–

6

White

F

FE

E

N/A (shield)

D

Length

Type

Length

Type

10 m (32 ft.)

W5010

50 m (164 ft.)

W5050

30 m (98 ft.)

W5030

100 m (328 ft.)

W5100

Voltage Level

5.5 V ± 5% (default)

12.0 V ± 5%

Jumper CN3

A+ A- B+ B- Z+ Z-

SD FE

IP IG AO IG BO IG ZO IG

A

B

C

D

E

F

G

H

TA1

TB1

TB2

(Pin)

3

4

5

6

E

1

2

PG encoder side

B

3

CN3

5.5 V 12 V

CN3

5.5 V 12 V

Advertising