C3: slip compensation, C3-01: slip compensation gain, C3-02: slip compensation primary delay time – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 165: C3-03: slip compensation limit, Common_tmo, 3 c: tuning

Advertising
background image

5.3 C: Tuning

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

165

P

a

ra

me

te

r De

ta

ils

5

Figure 5.7

Figure 5.7 Jerk Settings

When o1-03 is set to between 0 and 4, the jerk settings are expressed in seconds. Then the actual accel/decel time
including jerk settings can be calculated as follows:

Actual accel ramp = accel ramp setting + (C2-01 + C2-02) / 2

Actual decel ramp = decel ramp setting + (C2-03 + C2-04) / 2

C3: Slip Compensation

The Slip Compensation function improves the speed accuracy of an induction motor. By adjusting the output speed in
accordance with the motor load, it compensates the slip and makes the motor speed equal to the speed reference.

Note: Perform Auto-Tuning and make sure that the motor rated current (E2-01), the motor rated slip (E2-02), and the no-load current

(E2-03) have all been set properly before making any adjustments to slip compensation parameters.

C3-01: Slip Compensation Gain

Sets the gain for the motor slip compensation function. Although this parameter rarely needs to be changed, adjustments
may be necessary under the following circumstances:

• Increase the setting if the motor at constant speed is slower than the speed reference.
• Decrease the setting if the motor at constant speed is faster than the speed reference.

C3-02: Slip Compensation Primary Delay Time

Adjusts the filter on the output side of the slip compensation function. Although this parameter rarely needs to be
changed, adjustment may help in the following situations:

• Decrease the setting when the slip compensation response is too slow.
• Increase this setting when speed is unstable.

C3-03: Slip Compensation Limit

Sets the upper limit for the slip compensation function as a percentage of the motor rated slip (E2-02).

The slip compensation limit is constant throughout the constant torque range (speed reference

≤ E1-06). In the constant

power range (speed reference

≥ E1-06), it is increased based on C3-03 and the output speed as shown in

Figure 5.8

.

No.

Parameter Name

Setting Range

Default

C3-01

Slip Compensation Gain

0.0 to 2.5

1.0

No.

Parameter Name

Setting Range

Default

C3-02

Slip Compensation Primary Delay Time

0 to 10000 ms

2000 ms

No.

Parameter Name

Setting Range

Default

C3-03

Slip Compensation Limit

0 to 250%

200%

C2-05

C2-01

C2-02

C2-04

C2-03

Time

ON

Up/Down command

Output
speed

OFF

common_TMo

Advertising