o4-15: Maintenance Alarm Snooze Period

After a maintenance alarm output has been triggered, o4-15 determines the level that will trigger the next alarm for the
same component. The same alarm will be triggered by the detection level that triggered the original alarm plus the level
set in o4-15.

o4-16: Maintenance Monitoring Selection

Selects the Maintenance Monitor by using bits 0 to 3.

All bits = 0: Maintenance Monitors are disabled
bit 0: LT1 (cooling fan)
bit 1: LT2 (DC bus capacitors)
bit 2: LT3 (soft-charge bypass relay)
bit 3: LT4 (IGBTs have passed 90% of the their life expectancy)

No.

Parameter Name

Setting Range

Default

o4-15

<1> Parameter setting value is not reset to the default value during drive initialization (A1-03).

Maintenance Alarm Setting

0 to 20%

2%

<1>

No.

Parameter Name

Setting Range

Default

o4-16

<1> Parameter setting value is not reset to the default value during drive initialization (A1-03).

Maintenance Monitoring Selection

0000 to 1111

1000

<1>