B6: dwell function, B7: droop control (clv/pm), B6: dwell function b7: droop control (clv/pm) – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 160: Timer function operation, Common_tmo, 2 b: application

Advertising
background image

5.2 b: Application

160

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

Timer Function Operation

The timer function switches on when the timer function input closes for longer than the value set to b4-01. The timer
function switches off when the timer function input is open for longer than the value set to b4-02.

Figure 5.2

illustrates

the timer function operation:

Figure 5.2

Figure 5.2 Timer Operation

b6: Dwell Function

The Dwell function temporarily holds the frequency reference at a predefined value for a set time then continues
accelerating or decelerating.

Figure 5.3

shows how the Dwell function works.

Note: Set the stopping method to "Ramp to Stop" (b1-03 = 0) to use the Dwell function.

Figure 5.3

Figure 5.3 Dwell Function at Start and Stop

b6-01, b6-02: Dwell Speed, Dwell Time at Start

Parameter b6-01 determines the speed that is held or the time set in b6-02 during acceleration.

b6-03, b6-04: Dwell Speed, Dwell Time at Stop

Parameter b6-03 determines the speed that is held for the time set in b6-04 during deceleration.

b7: Droop Control (CLV/PM)

Droop control automatically balances the load level between two motors driving the same load. The drive in which Droop
control is activated shifts the load from one motor to another by automatically reducing the speed when the torque
reference rises, and automatically increasing the speed when the torque reference falls.

Note: Disable Inertia Compensation (n5-01 = 0) whenever using Droop control.

No.

Parameter Name

Setting Range

Default

b6-01

Dwell Speed at Start

<1> A setting of 100% is equal to the maximum speed.

0.0 to 100.0%

<1>

0.0%

b6-02

Dwell Time at Start

0.0 to 10.0 s

0.0 s

No.

Parameter Name

Setting Range

Default

b6-03

Dwell Speed at Stop

<1> A setting of 100% is equal to the maximum speed.

0.0 to 100.0%

<1>

0.0%

b6-04

Dwell Time at Stop

0.0 to 10.0 s

0.0 s

b4-01

b4-02

b4-01

b4-02

Multi-function Contact
Input: Timer Function

On (Closed)
Off (Open)

On (Closed)
Off (Open)

Multi-function Contact
Output: Timer Function

ON

ON

ON

ON

common_TMo

b6-01

b6-03

b6-02

b6-04

Up/Down Command

Output Speed

ON

OFF

OFF

common_TMo

Advertising