4.5 Auto-Tuning

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

115

St

ar

t-

U

p

Pr

og

ra

m

m

in

g

&

Op

er

at

io

n

4

Parameter Settings during Induction Motor Auto-Tuning: T1

The T1-†† parameters are used to set the Auto-Tuning input data for induction motor tuning.

Note: For motors operating in the field weakening range, first perform the Auto-Tuning with the base data. After Auto-Tuning is

complete, change E1-04, Maximum Output Frequency, to the desired value.

T1-01: Auto-Tuning Mode Selection

Sets the type of Auto-Tuning to be used.

Refer to Auto-Tuning for Induction Motors on page 109

for details on the

different types of Auto-Tuning.

Setting 0: Rotational Auto-Tuning
Setting 1: Stationary Auto-Tuning 1
Setting 2: Stationary Auto-Tuning for Line-to-Line Resistance
Setting 4: Stationary Auto-Tuning 2

T1-02: Motor Rated Power

Sets the motor rated power according to the motor nameplate value.

T1-03: Motor Rated Voltage

Sets the motor rated voltage according to the motor nameplate value. Enter the motor voltage at base speed here if the
motor is operating above base speed.

Enter the voltage needed to operate the motor under no-load conditions at rated speed to T1-03 for better control precision
around rated speed when using a vector control mode. The no-load voltage can usually be found in the motor test report
available from the manufacturer. If the motor test report is not available, enter approximately 90% of the rated voltage
printed on the motor nameplate. This may increase the output current and reduce the overload margin.

Step

Display/Result

1.

After entering the data listed on the motor nameplate, press

to confirm.

2.

Press

to activate Auto-Tuning. The drive begins by injecting current into the motor for about 1 min,

and then starts to rotate the motor.
Note: The first digit on the display indicates which motor is undergoing Auto-Tuning (motor 1 or motor 2). The
second digit indicates the type of Auto-Tuning being performed.

3.

Auto-Tuning finishes in approximately one to two minutes.

No.

Parameter Name

Setting Range

Default

T1-01

Auto-Tuning Mode Selection

2 (V/f)

0 to 2, 4 (OLV, CLV)

2 (V/f)

1 (OLV, CLV)

No.

Parameter Name

Setting Range

Default

T1-02

Motor Rated Power

0.00 to 650.00 kW

Determined by o2-04

No.

<1> Values shown are specific to 200 V class drives. Double value for 400 V class drives.

Parameter Name

Setting Range

Default

T1-03

Motor Rated Voltage

0.0 to 255.5 V

<1>

200.0 V

<1>

- A.TUNE -

0.00 Hz/ 0.00A

Tuning Ready ?

DRV

Auto-Tuning

ESC

FWD

Press RUN key

- A.TUNE -

X.XX Hz/ X.XXA

DRV

Tune Proceeding

Rdy

FWD







- MODE -

End

Tune Successful

DRV

FWD

RESET