5.5 E: Motor Parameters

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

183

P

a

ra

me

te

r De

ta

ils

5

E4: Motor 2 Parameters

E4 parameters contain the motor data for motor 2. These parameters are usually set automatically during the Auto-Tuning
process for vector control modes (Rotational Auto-Tuning, Stationary Auto-Tuning 1 and 2).

Refer to Auto-Tuning Fault

Detection on page 297

if Auto-Tuning cannot be performed.

Note: The function for switching between two motors cannot be used with a PM motor. E4-†† parameters are hidden when a PM

motor control mode is selected (A1-02 = 7).

E4-01: Motor 2 Rated Current

Protects the motor and calculates torque limits. Set E4-01 to the full load amps (FLA) stamped on the nameplate of motor
2.

If Auto-Tuning completes successfully, the value entered to T1-04 will automatically be saved to E4-01.

Note: 1. The display resolution depends on the rated output power of the drive. Models 2A0018 to 2A0041 and 4A0009 to 4A0023 display

values in 0.01 A units, while models 2A0059 to 2A0432 and 4A0030 to 4A0260 display values in 0.1 A units.

2. An oPE02 error will occur if the motor rated current in E4-01 is set lower than the motor no-load current in E4-03. Set E4-03 correctly

to prevent this error.

E4-02: Motor 2 Rated Slip

Sets the motor 2 rated slip frequency and is the basis for slip compensation value. The drive calculates this value
automatically during Auto-Tuning (Rotational Auto-Tuning and Stationary Auto-Tuning 1, 2).

Refer to E2-02: Motor

Rated Slip on page 179

for information on calculating the motor rated slip.

E4-03: Motor 2 Rated No-Load Current

Sets the no-load current for motor 2 in amperes when operating at the rated frequency and the no-load voltage. The drive

sets E2-03 during the Auto-Tuning process (Rotational Auto-Tuning and Stationary Auto-Tuning 1, 2). The motor no-

load current listed in the motor test report can also be entered to E2-03 manually. Contact the motor manufacturer for a

copy of the motor test report.

Note: The display resolution depends on the rated output power of the drive. Models 2A0018 to 2A0041 and 4A0009 to 4A0023 display

values in 0.01 A units, while models 2A0059 to 2A0432 and 4A0030 to 4A0260 display values in 0.1 A units.

E4-04: Motor 2 Motor Poles

Sets the number of poles for motor 2. If Auto-Tuning completes successfully, the value entered to T1-06 will be
automatically saved to E4-04.

No.

Parameter Name

Setting Range

Default

E4-01

Motor 2 Rated Current

10 to 200% of the drive rated current.

Determined by o2-04

No.

Parameter Name

Setting Range

Default

E4-02

Motor 2 Rated Slip

0.00 to 20.00 Hz

Determined by o2-04

No.

Parameter Name

Setting Range

Default

E4-03

Motor 2 Rated No-Load Current

0 to [E4-01]

Determined by o2-04

No.

Parameter Name

Setting Range

Default

E4-04

Motor 2 Motor Poles

2 to 48

4