C4: torque compensation, C3-23: motor 2 slip compensation limit, C4-01: torque compensation gain – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 167: Common_tmo, 3 c: tuning, Sets the gain for the torque compensation function

Advertising
background image

5.3 C: Tuning

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

167

P

a

ra

me

te

r De

ta

ils

5

C3-22: Motor 2 Slip Compensation Primary Delay Time

Functions for motor 2 in the same way that C3-02 functions for motor 1.

Refer to

C3-02: Slip Compensation Primary Delay Time on page 165

for instructions on how to adjust this parameter.

Note: The default for V/f Control (A1-02 = 0) is 2000 ms. The default for Open Loop Vector Control (A1-02 = 2) is 200 ms.

C3-23: Motor 2 Slip Compensation Limit

Sets the upper limit for the slip compensation function as a percentage of the motor rated slip (E4-02).

The slip compensation limit is constant throughout the constant torque range (frequency reference

≤ E3-06). In the

constant power range (frequency reference

≥ E3-06), it is increased based on C3-23 and the output frequency as shown in

the following diagram.

Figure 5.9

Figure 5.9 Slip Compensation Limit

C4: Torque Compensation

The torque compensation function compensates for insufficient torque production at start-up or when a load is applied.

Note: Set the motor parameters and V/f pattern properly before setting torque compensation parameters.

C4-01: Torque Compensation Gain

Sets the gain for the torque compensation function.

Torque Compensation in V/f:

The drive calculates the motor primary voltage loss using the output current and the line to line resistance (E2-05) and
then adjusts the output voltage to compensate insufficient torque at start or when load is applied. The effects of this
voltage compensation can be increased or decreased using parameter C4-01.

Torque Compensation in OLV:

The drive controls the motor excitation current (d-Axis current) and torque producing current (q-Axis current) separately.
Torque compensation affects the torque producing current only. C4-01 works as a factor of the torque reference value that
builds the torque producing current reference.

No.

Parameter Name

Setting Range

Default

C3-22

Motor 2 Slip Compensation Primary Delay Time

0 to 10000 ms

Determined by A1-02

No.

Parameter Name

Setting Range

Default

C3-23

Motor 2 Slip Compensation Limit

0 to 250%

200%

No.

Parameter Name

Setting Range

Default

C4-01

Torque Compensation Gain

0.00 to 2.50

1.00

E3-04
E3-06 × C3-23

C3-23

E3-04

Maximum

Frequency

E3-06

Base

Frequency

Output Frequency

common_TMo