Refer to sinking/sourcing, Refer to sinking, 9 control i/o configuration – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual
Page 80
Advertising
3.9 Control I/O Configuration
80
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
◆ Sinking/Sourcing Mode Selection for Safe Disable Inputs
Use jumper S3 on the terminal board to select between Sink mode, Source mode or external power supply for the Safe
Disable inputs H1 and H2 as shown in
(Default: Sink mode, internal power supply).
Table 3.11 Safe Disable Input Sink / Source / External Power Supply Selection
Drive Internal Power Supply
External 24 Vdc Power Supply
Sinking Mode
Sourcing Mode
24 Vdc
H1
H2
HC
Jumper S3
24 Vdc
H1
H2
HC
External
24 Vdc
Jumper S3
24 Vdc
H1
H2
HC
Jumper S3
24 Vdc
H1
H2
HC
External
24 Vdc
Jumper S3
Advertising