E5: pm motor settings, E4-05: motor 2 line-to-line resistance, E4-06: motor 2 leakage inductance – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual
Page 184: E5-02: motor rated power, E5-03: motor rated current, E5-04: number of motor poles, E5-05: motor stator resistance (single phase), 5 e: motor parameters

5.5 E: Motor Parameters
184
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
■
E4-05: Motor 2 Line-to-Line Resistance
Sets the line-to-line resistance for the motor 2 stator winding. If Auto-Tuning completes successfully, this value is
automatically calculated. Enter this value as line-to-line and not for each motor phase.
Refer to E2-05: Motor Line-to-
to manually enter this parameter setting.
■
E4-06: Motor 2 Leakage Inductance
Sets the voltage drop due to motor leakage inductance as a percentage of rated voltage of motor 2. This value is
automatically set during Auto-Tuning (Rotational Auto-Tuning and Stationary Auto-Tuning 1, 2).
◆ E5: PM Motor Settings
These parameters set the motor data of a PM motor.
For PM motors, Auto-Tuning can be performed. If motor data is known, it can also be entered manually.
Note: 1. E5- parameters are visible only when a PM motor control mode is selected (A1-02 = 7).
2. E5- parameters are not reset when the drive is initialized using parameter A1-03.
■
E5-02: Motor Rated Power
Sets the rated power of the motor. Determined by the value set to T2-04 during the Auto-Tuning process.
■
E5-03: Motor Rated Current
Sets the motor rated current in amps. Automatically set when the value is entered to T2-06 during Auto-Tuning.
Note: The display resolution depends on the rated output power of the drive. Models 2A0018 to 2A0041 and 4A0009 to 4A0023 display
values in 0.01 A units, while models 2A0059 to 2A0432 and 4A0030 to 4A0260 display values in 0.1 A units.
■
E5-04: Number of Motor Poles
Sets the number of motor poles. Automatically set when the value is entered to T2-08 during Auto-Tuning.
■
E5-05: Motor Stator Resistance (Single Phase)
Sets the resistance for one motor phase. Do not enter the line-to-line resistance into E5-05 when measuring the resistance
manually.
No.
Parameter Name
Setting Range
Default
E4-05
Motor 2 Line-to-Line Resistance
0.000 to 65.000
Ω
Determined by o2-04
No.
Parameter Name
Setting Range
Default
E4-06
Motor 2 Leakage Inductance
0.0 to 40.0%
Determined by o2-04
No.
Parameter Name
Setting Range
Default
E5-02
Motor Rated Power
0.10 to 650.00 kW
Determined by o2-04
No.
Parameter Name
Setting Range
Default
E5-03
Motor Rated Current
10 to 200% of drive rated current
Determined by o2-04
No.
<1> When PG-E3 option connected: Max. setting = 48.
Parameter Name
Setting Range
Default
E5-04
Number of Motor Poles
2 to 120
12
No.
Parameter Name
Setting Range
Default
E5-05
Motor Stator Resistance (Single Phase)
0.000 to 65.000
Ω
Determined by o2-04