Motor switch selection, D1-27: motor 2 speed reference, D1-28: leveling speed detection level – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 176: D1-29: inspection speed detection level, 4 d: reference settings, Sets the speed reference for motor 2

Advertising
background image

5.4 d: Reference Settings

176

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

Motor Switch Selection

When an input terminal selects motor 2 (H1-††= 16), the drive will operate a second motor using V/f Control. The drive
cannot control motor 2 with OLV, CLV or CLV/PM.

The motor 2 speed reference in d1-27 can also be used to operate motor 1 using V/f Control. Refer to

Table 5.8

for

combinations of selecting the speed reference for motor 2 and the motor 1/2 selection switch. (H1-†† = 53).

Table 5.8 Speed Reference for Motor 2, Controlling Motor 1 and 2

d1-27: Motor 2 Speed Reference

Sets the speed reference for motor 2.

Note: 1. The drive will control motor 1 when this parameter is set to 0.00.

2. Set the accel/decel times in parameters C1-12 and C1-13 when using motor 2.
3. When motor 2 is selected, the following monitors will display values in Hz: U1-01, U1-02, U1-05, U4-19, U4-20.

d1-28: Leveling Speed Detection Level

When the speed priority selection in d1-18 is set to “0” or “3” and the speed reference value falls below the level set in d1-
28, the drive interprets the selected speed as leveling speed. This parameter must be set to use the Speed Control Loop
setting 3 when d1-18 = 0/3.

Refer to C5: Speed Control Loop on page 169

for details.

d1-29: Inspection Speed Detection Level

When the speed priority selection in d1-18 is set to “0” or “3” and the speed reference value is below the level set in d1-
29 but higher than the level set in d1-28, the drive interprets the selected speed as inspection speed. This parameter must
be set to use the Inspection Operation function when d1-18 = 0/3.

Refer to Inspection Operation on page 124

for details.

The value set to d1-27

<1> Enter the same values to the E3 and E4 parameters that are set for the E1 and E2 parameters.

Speed reference

Control mode

Accel/Decel ramp

S-character/ Jerk

Contactor/

Brake sequence

Purpose

0.00

speed reference set to

Motor 1

V/f with motor 1

<1>

C1-01 to C1-08

C2-01 to C2-05

Available

Hoist

not 0.00

d1-27

V/f with motor 2

C1-12/C1-13

N.A.

N.A.

Not for hoist

No.

Parameter Name

Setting Range

Default

d1-27

Motor 2 Speed Reference

0.00 to 120.00 Hz

0.00 Hz

No.

Parameter Name

Setting Range

Default

d1-28

Leveling Speed Detection Level

0.0 to 100.0%

0.0%

No.

Parameter Name

Setting Range

Default

d1-29

Inspection Speed Detection Level

0.0 to 100.0%

0.0%