E: motor parameters, D6: field forcing, E1: v/f pattern – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 375: B.3 parameter table

Advertising
background image

B.3 Parameter Table

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

375

Pa

ra

met

er

L

is

t

B

d6: Field Forcing

E: Motor Parameters

E1: V/f Pattern

d1-23

(2C5H)

Releveling Speed

Sets speed reference for releveling when d1-18 = 1 or 2.

Default: 0.00%

<6>

Min: 0.00%
Max: 100.00%

<6>

175

d1-24

(2C6H)

Inspection Operation Speed

Sets speed reference when inspection operation is enabled.

Default: 50.00%

<6>

Min: 0.00%
Max: 100.00%

<6>

175

d1-25

(2C7H)

Rescue Operation Speed

Sets the speed reference during inspection operation.

Default: 10.00%

<6>

Min: 0.00%
Max: 100.00%

<6>

175

d1-26

(2C8H)

Leveling Speed

Sets leveling speed reference when d1-18 = 1 or 2.

Default: 8.00%

<6>

Min: 0.00%
Max: 100.00%

<6>

175

d1-27

(2C9H)

Motor 2 Speed Reference

Sets the speed reference for motor 2.
Note: 1. If set to 0.00, the drive will control motor 1 instead.

2. When using motor 2, be sure that the accel/decel times are set in parameters C1-12

and C1-13.

Default: 0.00 Hz
Min: 0.00 Hz
Max: 200.00 Hz

176

d1-28

(2CAH)

Leveling Speed Detection Level

Used when d1-18 = 0 or 3. If the speed reference selected is lower than d1-28, then the drive
uses the leveling speed as the speed reference.

Default: 0.0%
Min: 0.0%
Max: 100.0%

176

d1-29

(2CBH)

Inspection Speed Detection Level

Used when d1-18 = 0 or 3. If the speed reference selected is higher than d1-28 but lower or
equal to d1-29, then the drive uses inspection speed as the speed reference.

Default: 0.0%
Min: 0.0%
Max: 100.0%

176

<6> Setting ranges and defaults vary by the setting units determined by parameter o1-03.

Refer to Defaults and Setting Ranges by Display Unit Selection (o1-03) on page 416

.

No.(Addr.)

Name

Description

Setting

Page

d6-03

(2A2H)

Field Forcing Selection

0: Disabled
1: Enabled

Default: 0

Min: 0
Max: 1

177

d6-06

(2A5H)

Field Forcing Limit

Sets the upper limit of the excitation current command during magnetic field forcing. A setting
of 100% is equal to motor no-load current. Disabled only during DC Injection Braking.

Default: 400%

Min: 100%
Max: 400%

177

No.(Addr.)

Name

Description

Setting

Page

E1-01

(300H)

Input Voltage Setting

This parameter must be set to the power supply voltage.
WARNING! Electrical Shock Hazard. Drive input voltage (not motor voltage) must be set in
E1-01 for the protective features of the drive to function properly. Failure to do so may result in
equipment damage and/or death or personal injury.

Default: 230 V

<9>

Min: 155 V
Max: 255 V

<9>

178

E1-03

(302H)

V/f Pattern Selection

F: Custom V/f, E1-04 through E1-13 settings define the V/f pattern

Default: F

Min: –
Max: F

178

No.(Addr.)

Name

Description

Setting

Page

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

CLV

CLV/PM

V/f

OLV

common

_

All Modes

common

_

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV