YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

B.3 Parameter Table

B.3 Parameter Table

A: Initialization Parameters

The A parameter group creates the operating environment for the drive. This includes the parameter Access Level, Motor
Control Method, Password, User Parameters and more.

A1: Initialization Parameters

A2: User Parameters

No.(Addr.)

Name

Description

Setting

Page

A1-00

(100H)

<1>

<1> Parameter setting value is not reset to the default value when the drive is initialized.

<2> Settings 8 to 12 can only be selected from an LCD operator with software version 0102 or later. The version number of the LCD operator PRG

software is shown on the back of the LCD operator.

Language Selection

0: English
1: Japanese
2: German
3: French
4: Italian
5: Spanish
6: Portuguese
7: Chinese
8: Czech
9: Russian
10: Turkish
11: Polish
12: Greek

Default: 0
Min: 0
Max: 12

<2>

150

A1-01

(101H)

Access Level Selection

0: View and set A1-01 and A1-04. U†-†† parameters can also be viewed.
1: User Parameters (access to a set of parameters selected by the user, A2-01 to A2-32)
2: Advanced Access (access to view and set all parameters)

Default: 2

Min: 0
Max: 2

150

A1-02

(102H)

<1>

Control Method Selection

0: V/f Control
2: Open Loop Vector Control
3: Closed Loop Vector Control
7: Closed Loop Vector Control for PM Motors

Default: 2
Min: 0
Max: 7

151

A1-03

(103H)

Initialize Parameters

0: No initialization
1110: User Initialize (parameter values must be stored using parameter o2-03)
2220: 2-wire initialization
5550: oPE04 error reset

Default: 0

Min: 0
Max: 5550

151

A1-04

(104H)

Password

When the value set into A1-04 does not match the value set into A1-05, parameters A1-01
through A1-03, and A2-01 through A2-33 cannot be changed.

Default: 0000

Min: 0000
Max: 9999

152

A1-05

(105H)

Password Setting

152

No.(Addr.)

Name

Description

Setting

Page

A2-01 to

A2-32

(106 to 125H)

<5> Default setting is determined by the control mode (A1-02).

User Parameters 1 to 32

Parameters that were recently edited are listed here. The user can also select parameters to
appear here for quick access.

Default:

<5>

Min: A1-00
Max: o4-16

155

A2-33

(126H)

User Parameter Automatic
Selection

0: Parameters A2-01 through A2-32 are reserved for the user to create a list of User Parameters.
1: Save history of recently viewed parameters. Recently edited parameters will be saved to A2-
17 through A2-32 for quick access.

Default: 1

Min: 0
Max: 1

155

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_