C.3 Connecting to a Network

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

421

MEMOBUS

/Mo

dbu

s

C

o

m

m

u

ni

ca

ti

on

s

C

RS-422 Interface

Figure C.4

Figure C.4 RS-422 Interface

Note: 1. Turn on the DIP switch on the drive that is located at the end of the network. All other slave devices must have this DIP switch set to

the OFF position.

2. Set H5-07 to 0 when using the RS-485 interface.

Set H5-07 to 1 when using the RS-422 interface in multi-drop circuit. Set H5-07 to 0 when using the RS-422 interface in point-to-
point circuit.

Network Termination

The two ends of the MEMOBUS/Modbus network line have to be terminated. The drive has a built in termination resistor
that can be enabled or disabled using DIP switch S2. If a drive is located at the end of a network line, enable the
termination resistor by setting DIP switch S2 to the ON position. Disable the termination resistor on all slaves that are not
located at the network line end.

Figure C.5

illustrates the setting of DIP switch S2.

To set the DIP switch on the terminal board, use an appropriate sized tool with a tip of approximately 8 mm (5/16 in.) in
width.

Figure C.5

Figure C.5 Serial Communications Terminal and DIP Switch S2

R–
R+
S–
S+

IG

PLC

Drive

Drive

Drive

S–
S+
R–
R+
IG

S–
S+
R–
R+
IG

S–
S+
R–
R+
IG

S2

OFF

S2

OFF

S2

ON

c o m -

mon_

TMonly

RS-422

or

RS-485

R-

R+

DIP

switch

S2

S-

S+

+

-

Termination resistor (1/2 W

, 110

Ω)

DIP Switch S2

(OFF: default)

OFF

ON

YEA_T

M

only