Terminal configuration, Serial communication terminals, Wire size and torque specifications – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 75: Yea_common, 8 control circuit wiring, Table 3.8 wire gauges and torque specifications

Advertising
background image

3.8 Control Circuit Wiring

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

75

El

ec

tr

ic

al

In

st

al

la

ti

o

n

3

Serial Communication Terminals

Table 3.7 Control Circuit Terminals: Serial Communications

Terminal Configuration

Control circuit terminals are arranged as shown in

Figure 3.19

.

Figure 3.18

Figure 3.19 Control Circuit Terminal Arrangement

Wire Size and Torque Specifications

WARNING! Fire hazard. Tighten all terminal screws to the specified tightening torque. Loose electrical connections could result in

death or serious injury by fire due to overheating of electrical connections. Improperly tightened terminal screws can also cause

erroneous equipment operation.

Select appropriate wire type and gauges from

Table 3.8

. For simpler and more reliable wiring, use crimp ferrules on the

wire ends. Refer to

Table 3.9

for ferrule terminal types and sizes.

Table 3.8 Wire Gauges and Torque Specifications

Type

<1> Enable the termination resistor in the last drive in a MEMOBUS network by setting DIP switch S2 to the ON position. For more information on

the termination resistor,

Refer to Control I/O Configuration on page 79

.

No.

Signal Name

Function (Signal Level)

MEMOBUS/Modbus
Communication

<1>

R+

Communications input (+)

MEMOBUS/Modbus communication: Use an RS-485 or
RS-422 cable to connect the drive.

RS-485/422
MEMOBUS/Modbus
communication protocol
115.2 kbps (max.)

R-

Communications input (-)

S+

Communications output (+)

S-

Communications output (-)

IG

Shield ground

0 V

Terminal

Block

Terminal

Size

Tightening

Torque

N"m

(lb.in.)

Bare Wire Terminal

Ferrule-Type Terminal

Applicable Wire

Size

mm

2

(AWG)

Recomm. mm

2

(AWG)

Applicable Wire

Size

mm

2

(AWG)

Recomm. mm

2

(AWG)

Wire Type

TB1, TB2,
TB4, TB5,

TB6

FM, AC, AM, P1, P2,
PC, SC, A1, A2, A3,
+V, -V, S1-S8, MA,
MB, MC, M1, M2, HC,
H1, H2, DM+, DM-, IG,
R+, R-, S+, S-, RP, MP,
E (G)

M2

0.22 to 0.25

(1.9 to 2.2)

Standard wire:

0.25 to 1.0

(24 to 17)

Solid wire:

0.25 to 1.5

(24 to 16)

0.75

(18)

0.25 to 0.5

(24 to 20)

0.5

(20)

Shielded wire, etc.

E(G) HC H1

H2 DM+ DM- IG

R+

R-

S+

S-

S1

S2

S3

S4

S5

S6

S7

S8

SN SC SP

V+ AC

V-

A1

A2 FM AM AC

P1

C1

C2

P2

M3 M4

M6

MA MB MC

M1 M2 M5

YEA_common