7 h: terminal functions – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 199

Advertising
background image

5.7 H: Terminal Functions

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

199

P

a

ra

me

te

r De

ta

ils

5

Setting 2: Speed agree 1 (f

ref

/f

out

Agree 1)

Closes whenever the actual output speed (CLV, CLV/PM) is within the Speed Agree Width (L4-02) of the current speed
reference regardless of the direction.

Note: Detection works in both directions, forward and reverse.

Figure 5.19

Figure 5.19 Speed Agree 1 Time Chart

Refer to L4-01, L4-02: Speed Agreement Detection Level and Detection Width on page 219

for more details.

Status

Description

Open

Output speed or motor speed does not match the speed reference while the drive is running.

Closed

Output speed or motor speed is within the range of speed reference ±L4-02.

L4-02

L4-02

Speed

reference

Speed agree 1

ON

OFF

Output speed

or motor speed

Advertising