C: tuning, B6: dwell function, B7: droop control – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 370: B8: energy saving, C1: acceleration and deceleration ramps, B.3 parameter table

Advertising
background image

B.3 Parameter Table

370

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

b6: Dwell Function

b7: Droop Control

b8: Energy Saving

C: Tuning

C parameters are used to adjust the acceleration and deceleration ramps, jerk settings, slip compensation, torque
compensation, and carrier frequency selections.

C1: Acceleration and Deceleration Ramps

No.(Addr.)

Name

Description

Setting

Page

b6-01

(1B6H)

Dwell Speed at Start

Parameters b6-01 and b6-02 set the speed to hold and the time to maintain that speed at start.
Parameters b6-03 and b6-04 set the speed to hold and the time to maintain that speed at stop.

Default: 0.0%

Min: 0.0%
Max: 100.0%

160

b6-02

(1B7H)

Dwell Time at Start

Default: 0.0 s

Min: 0.0 s
Max: 10.0 s

b6-03

(1B8H)

Dwell Speed at Stop

Default: 0.0%

Min: 0.0%
Max: 100.0%

160

b6-04

(1B9H)

Dwell Time at Stop

Default: 0.0 s

Min: 0.0 s
Max: 10.0 s

No.(Addr.)

Name

Description

Setting

Page

b7-01

(1CAH)

Droop Control Gain

Sets the speed reduction gain applied at a torque reference of 100%. Set as a percentage of
motor base speed.

Default: 0.0%

Min: 0.0%
Max: 100.0%

161

b7-02

(1CBH)

Droop Control Delay Time

Used to adjust the responsiveness of Droop Control.

Default: 0.05 s

Min: 0.03 s
Max: 2.00 s

161

No.(Addr.)

Name

Description

Setting

Page

b8-01

(1CCH)

Energy Saving Control Selection

0: Disabled
1: Enabled

Default: 0

Min: 0
Max: 1

161

b8-16

(1F8H)

Energy Saving Control Constant
(Ki)

Enter the Energy Saving value (Ki) as specified on the motor name plate. (for IPM motors only)

Default: 0.10
Min: 0.00
Max: 2.00

161

b8-17

(1F9H)

Energy Saving Control Constant
(Kt)

Enter the Energy Saving value (Kt) as specified on the motor name plate. (for IPM motors only)

Default: 1.00
Min: 0.00
Max: 2.00

161

No. (Addr.)

Name

Description

Setting

Page

C1-01

(200H)

Acceleration Ramp 1

Sets the ramp to accelerate from 0 to maximum speed.

Default: 1.50 s

<6> <8>

Min: 0.00 s
Max: 600.00 s

<6> <8>

162

C1-02

(201H)

Deceleration Ramp 1

Sets the ramp to decelerate from maximum speed to 0.

C1-03

(202H)

Acceleration Ramp 2

Sets the ramp to accelerate from 0 to maximum speed.

C1-04

(203H)

Deceleration Ramp 2

Sets the ramp to decelerate from maximum speed to 0.

C1-05

(204H)

Acceleration Ramp 3 (Motor 2
Accel Time 1)

Sets the ramp to accelerate from 0 to maximum speed.

All Modes

common

_

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

common

_

CLV

CLV/PM

V/f

OLV

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

Advertising