T2-17: pg encoder z-pulse offset, 5 auto-tuning – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 119

Advertising
background image

4.5 Auto-Tuning

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

119

St

ar

t-

U

p

Pr

og

ra

m

m

in

g

&

Op

er

at

io

n

4

T2-16: PG Number of Pulses Per Revolution for PM Motor Tuning

Enter the number of pulses from the PG encoder per motor rotation.

T2-17: PG Encoder Z-pulse Offset

Sets the offset between the rotor magnet axis and the PG encoder zero position. If the PG encoder offset value is unknown
or if the PG encoder is replaced, perform PG Encoder Offset Auto-Tuning.

T2-18: Speed Reference for Auto-Tuning of PG-E3 Encoder Characteristics

Sets the speed reference for execution of Auto-Tuning of PG-E3 Encoder Characteristics.

T2-19: Rotation Direction for Auto-Tuning of PG-E3 Encoder Characteristics

Sets the direction of motor rotation of Auto-Tuning of PG-E3 Encoder Characteristics.

Setting 0: Forward (Up)
Setting 1: Reverse (Down)

No.

Parameter Name

Setting Range

Default

T2-16

Encoder Resolution (Pulses Per Revolution)

1 to 15000 ppr

1024 ppr

No.

Parameter Name

Setting Range

Default

T2-17

PG Encoder Z-pulse Offset

-180.0 to 180.0 deg

0.0 deg

No.

Parameter Name

Setting Range

Default

T2-18

Speed Reference for Auto-Tuning of PG-E3 Encoder Characteristics

1 to 30 r/min

10 r/min

No.

Parameter Name

Setting Range

Default

T2-19

Rotation Direction for Auto-Tuning of PG-E3 Encoder Characteristics

0, 1

0