background image

4.3 The Drive and Programming Modes

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

99

St

ar

t-

U

p

Pr

og

ra

m

m

in

g

&

Op

er

at

io

n

4

Simplified Setup Using the Setup Group

In the Setup Group, the drive lists the basic parameters needed to set up the drive for an elevator application. This group
expedites the startup process for an elevator application by showing only the most important parameters for the
application.

Using the Setup Group

Figure 4.11

illustrates how to enter and how to change parameters in the Setup Group.

The first display shown when entering the Setup Group is the Control Method menu. Skipping this display will keep the
current Setup Group parameter selection. The default setting for the Setup Group is a group of parameters most
commonly use in control methods.

In this example, the Setup Group is accessed to change b1-01 from 0 to 1. This changes the source of the speed reference
from the digital operator to the control circuit terminals.

Figure 4.11 Setup Group Example

<1> Use the up and down arrow keys to scroll through the Setup Group. Press the ENTER key to view or change parameter settings.

<2> To return to the previous menu without saving changes, press the ESC key.

φ

ψ

φ

ψ

- MODE -

U1-01= 0.00%

U1-02= 0.00%
U1-03= 0.00A

DRV

Speed Ref (OPR)

Rdy

RSEQ
LREF

Control Circuit

Terminal

Operator

<1>

<2>

<2>

Speed reference

appears when

powered up

HELP

- MODE -

PRG

Quick Setting

DATA

FWD

Entry Accepted

- SETUP -

b1-01

= 0

∗0∗

Operator

PRG

Speed Ref Sel

Rdy

Home

FWD

DATA

- SETUP -

A1-02

= 2

∗2∗

Open Loop Vector

PRG

Control Method

Rdy

Home

FWD

DATA

- SETUP -

b1-02

= 1

∗1∗

Digital Inputs

PRG

Up/Dn Command Sel

Rdy

Home

FWD

DATA

- SETUP -

L3-01

= 1

∗1∗

General Purpose

PRG

StallP Accel Sel

Rdy

Home

FWD

DATA

“1”

- SETUP -

b1-01=

0

∗0∗

Operator

PRG

Speed Ref Sel

Rdy

FWD

“1”

- SETUP -

b1-01=

0

∗0∗

Analog Input

PRG

Speed Ref Sel

Rdy

FWD

FWD