A.1 three-phase 200 v class drives, Table a.1 power ratings (three-phase 200 v class) – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 358

Advertising
background image

358

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

A.1 Three-Phase 200 V Class Drives

A.1 Three-Phase 200 V Class Drives

Table A.1 Power Ratings (Three-Phase 200 V Class)

Item

<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than

the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.

<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring

connections, and power supply impedance.

<3> DC is not available for UL standards.

<4> Rated motor capacity is calculated with a rated output voltage of 220 V.

<5> Carrier frequency can be set up to 8 kHz while keeping this current rating. Higher carrier frequency settings require derating.

<6> Carrier frequency can be set up to 5 kHz while keeping this current rating. Higher carrier frequency settings require derating.

Specification

CIMR-LE2A

0018

0022

0031

0041

0059

0075

0094

0106

0144

0181

0225

0269

0354

0432

Maximum Applicable Motor Capacity (HP)

<1>

5

7.5

10

15

20

25

30

40

50

60

75

100

125

150

Input

Input Current (A)

<2>

15.6

18.9

28

37

52

68

80

82

111

136

164

200

271

324

Rated Voltage

Rated Frequency

Three-phase 200 to 240 Vac 50/60 Hz/270 to 340 Vdc

<3>

Allowable Voltage Fluctuation

-15 to 10%

Allowable Frequency Fluctuation

±5%

Input Power (kVA)

7.8

9.5

14

18

27

36

44

37

51

62

75

91

124

148

Output

Rated Output Capacity (kVA)

<4>

5.3

<5>

6.7

<5>

9.5

<5>

12.6

<5>

17.9

<5>

23

<5>

29

<5>

32

<5>

44

<5>

55

<6>

69

<6>

82

<6>

108

<6>

132

<6>

Rated Output Current

(3 minutes, 50% ED) (A)

17.5

<5>

21.9

<5>

31.3

<5>

41.3

<5>

58.8

<5>

75.0

<5>

93.8

<5>

106.3

<5>

143.8

<5>

181.3

<6>

225.0

<6>

268.8

<6>

353.8

<6>

432.5

<6>

Overload Tolerance

133% of rated output current for 30 s

Carrier Frequency

User adjustable between 2 and 15 kHz

User adjustable between 2 and 10 kHz

Maximum Output Voltage (V)

Three-phase 200 to 240 V (proportional to input voltage)

Maximum Output Speed (Hz)

120 Hz (user-set)

Advertising