5.8 L: Protection Functions

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

225

P

a

ra

me

te

r De

ta

ils

5

L7-01 to L7-04: Torque Limits

These parameters set the torque limits in each operation mode.

A setting of 100% is equal to the motor rated torque.

L7-16: Torque Limit Process at Start

Assigns a time filter to allow the torque limit to build at start.

Setting 0: Disabled

Toque limit is created at start without a delay time. Disable L7-16 to maximize response time when the application
requires sudden acceleration or deceleration at start.

Setting 1: Enabled

A time filter is added to allow the torque limit to build at start.

L8: Drive Protection

L8-02: Overheat Alarm Level

Sets the overheat alarm (oH) detection level.

The drive will output an alarm when the heatsink temperature exceeds the alarm level set in parameter L8-02.

When an output terminal is set for the oH pre-alarm (H2-†† = 20), the switch will close when the heatsink temperature
rises above L8-02.

L8-03: Overheat Pre-Alarm Operation Selection

Sets the operation when an overheat pre-alarm is detected.

Setting 0: Ramp to stop

If an overheat alarm occurs, the drive decelerates to stop using the deceleration ramp currently selected. If a digital output
is programmed for “fault” (H2-†† = E), this output will be triggered.

Setting 1: Coast to stop

If heatsink overheat (oH) occurs, the drive switches off the output and the motor coasts to stop. If a digital output is
programmed for “fault” (H2-†† = E), this output will be triggered.

Setting 2: Fast Stop

If an overheat alarm occurs, the drive decelerates to stop using the Fast Stop ramp (C1-09). If a digital output is
programmed for “fault” (H2-†† = E), this output will be triggered.

No.

Parameter Name

Setting Range

Default

L7-01

Forward Torque Limit

0 to 300%

200%

L7-02

Reverse Torque Limit

0 to 300%

200%

L7-03

Forward Regenerative Torque Limit

0 to 300%

200%

L7-04

Reverse Regenerative Torque Limit

0 to 300%

200%

No.

Parameter Name

Setting Range

Default

L7-16

Torque Limit Process at Start

0 to 1

1

No.

Parameter Name

Setting Range

Default

L8-02

Overheat Alarm Level

50 to 150°C

Determined by o2-04

No.

Parameter Name

Setting Range

Default

L8-03

Overheat Pre-Alarm Operation Selection

0 to 3

3