C.4 MEMOBUS/Modbus Setup Parameters
424
YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual
■
H5-10: Unit Selection for MEMOBUS/Modbus Register 0025H
Sets the unit for the output voltage monitor value in MEMOBUS/Modbus register 0025H.
Setting 0: 0.1 V units
Setting 1: 1 V units
■
H5-11: Communications Enter Function Selection
Selects whether an Enter command is necessary is needed to change parameter values via MEMOBUS/Modbus
communications.
Refer to Enter Command on page 442
.
Setting 0: Enter command necessary
Parameter changes become effective after an Enter command. An Enter command must only be sent after the last
parameter change, not for each single parameter.
Setting 1: Enter command not necessary
Parameter value changes become effective immediately without the need to send an Enter command.
No.
Parameter Name
Setting Range
Default
H5-10
Unit Selection for MEMOBUS/Modbus Register 0025H
0 or 1
0
No.
Parameter Name
Setting Range
Default
H5-11
Communications Enter Function Selection
0 or 1
0