6 auto-tuning fault detection – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 300

Advertising
background image

6.6 Auto-Tuning Fault Detection

300

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

Digital Operator Display

Error Name

Er-21

Z Pulse Correction Error

Cause

Possible Solutions

Motor was coasting when Auto-Tuning was
performed.

Make sure the motor has stopped completely. Repeat Auto-Tuning.

Either the motor or the encoder on the motor is not
properly wired.

Check the wiring for the motor and the encoder. Repeat Auto-Tuning.

The direction for the encoder is set incorrectly, or the
number of pulses set for the encoder is wrong.

Check the direction setting by F1-05 and b1-14 and number of pulses (F1-01) set for the encoder. Repeat Auto-Tuning.

Encoder is damaged.

Check the signal output from the encoder attached to the motor. Replace the encoder if damaged.

Excess position error detected for the PG-E3 speed-
control option card with the ERN1387 encoder.

If other possible solutions are not successful, perform Auto-Tuning of PG-E3 encoder characteristics.

Digital Operator Display

Error Name

Er-22

Initial Rotor Pole Search Error

Cause

Possible Solutions

Parameters set by Initial Rotor Pole Search Tuning
were outside the acceptable range.

Switch to an absolute encoder and to the PG-F3 option card.

During normal operation, pole diversion exceeded
20 degrees.

Digital Operator Display

Error Name

Er-23

Non-rotating Encoder Offset Tuning Warning

Cause

Possible Solutions

Pole diversion exceeded 15 degrees three times.

Remove the ropes and conduct Rotational Auto-Tuning for Encoder Offset (T2-01 = 3).

Parameters set by Encoder Offset Tuning were
outside the acceptable range.

Digital Operator Display

Error Name

Er-24

Auto-Tuning Error for PG-E3 Encoder Characteristics

Cause

Possible Solutions

The signal lines between the PG-E3 option card and
encoder are disconnected at the R+ and R- terminals.

Refer to the installation manual for the PG-E3 option card for information on correct connection of signal lines.

Excessive electrical interference at the PG-E3 option
card
The software for the PG-E3 option card does not
support the Auto-Tuning of PG-E3 encoder
characteristics.

Check the software version (PRG) for the PG-E3 option card. The software version PRG: 1102 and later support Auto-Tuning of

PG-E3 encoder characteristics.

Advertising