Yea_ tmonly yea_ tmonly, 4 drive cooling fans and circulation fans – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 323

Advertising
background image

7.4 Drive Cooling Fans and Circulation Fans

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

323

Pe

ri

od

ic

In

spe

ct

io

n

&

Main

tenan

ce

7

3.

Angle the fan cover as shown in

Figure 7.15

and insert the connector tabs into the corresponding holes on the

drive.

Figure 7.17

Figure 7.17 Reattach the Fan Cover: 4A0094, 4A0114

4.

While pressing in on the hooks of the left and right sides of the fan cover, guide the fan finger guard until it clicks
back into place.

Figure 7.18

Figure 7.18 Reattach the Fan Cover: 4A0094, 4A0114

5.

Turn the power supply back on and reset the cooling fan operation time for the Maintenance Monitor by setting
o4-03 to 0.

Front of Drive

Back of Drive

Hook

Fan finger guard

Hook

Four tabs

Holes for connector tabs.

YEA_

TMonly

YEA_

TMonly

Advertising