H3-09: terminal a2 signal level selection, Common_tmo, 7 h: terminal functions – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 208: Selects the input signal level for analog input a2

Advertising
background image

5.7 H: Terminal Functions

208

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

H3-03, H3-04: Terminal A1 Gain and Bias Settings

Parameter H3-03 sets the level of the selected input value that is equal to 10 Vdc input at terminal A1 (gain).

Parameter H3-04 sets the level of the selected input value that is equal to 0 V input at terminal A1 (bias).

Both can be used to adjust the characteristics of the analog input signal to terminal A1.

Setting Examples

• Gain H3-03 = 200%, bias H3-04 = 0, terminal A1 as speed reference input (H3-02 = 0):

A 10 Vdc input is equivalent to a 200% speed reference and 5 Vdc is equivalent to a 100% speed reference. Since the
drive output is limited by the maximum frequency parameter (E1-04), the speed reference will be equal to E1-04 above
5 Vdc.

Figure 5.29

Figure 5.29 Speed Reference Setting by Analog Input with Increased Gain

• Gain H3-03 = 100%, bias H3-04 = -25%, terminal A1 as speed reference input:

An input of 0 Vdc will be equivalent to a -25% speed reference.
When parameter H3-01 = 0, the speed reference is 0% between 0 and 2 Vdc input.
When parameter H3-01 = 1, the motor will rotate in reverse between -10 and 2 Vdc input.

Figure 5.30

Figure 5.30 Speed Reference Setting by Analog Input with Negative Bias

H3-09: Terminal A2 Signal Level Selection

Selects the input signal level for analog input A2.

Setting 0: 0 to 10 Vdc

The input level is 0 to 10 Vdc. Refer to

Setting 0: 0 to 10 Vdc on page 207

for details.

No.

Parameter Name

Setting Range

Default

H3-03

Terminal A1 Gain Setting

-999.9 to 999.9%

100.0%

H3-04

Terminal A1 Bias Setting

-999.9 to 999.9%

0.0%

No.

Parameter Name

Setting Range

Default

H3-09

Terminal A2 Signal Level Selection

0 or 1

0

100%

-100%

5 V

10 V

-5 V

-10 V

E1-04

E1-04

H3-01 = 0

H3-01 = 1

0 V

10 V

5 V

0 V

Gain = 200 %

Gain = 200 %

100 %

Speed
reference

Bias = 0 %

E1-04

Gain = -200 %

common_TMo

2.0 V

10 V

-6.0 V

-10 V

E1-04

0

-100%

-150%

2.0 V

10 V

100 %

Speed
reference

-25%

-25%

H3-01 = 0

H3-01 = 1

H3-01 = 0

H3-01 = 1

100%

Analog Input

Voltage

Analog Input

Voltage

common_TMo

Advertising