B.3 parameter table – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 388

Advertising
background image

B.3 Parameter Table

388

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

H5: MEMOBUS/Modbus Serial Communication

Note: The settings for MEMOBUS/Modbus communications become effective when the drive is restarted.

H4-06

(422H)

Terminal AM Bias

Sets the bias value added to the terminal AM output signal.

Default: 0.0%

Min: -999.9%
Max: 999.9%

211

H4-07

(423H)

Terminal FM Signal Level
Selection

0: 0 to 10 V
1: –10 to 10 V

Default: 0
Min: 0
Max: 1

212

H4-08

(424H)

Terminal AM Signal Level
Selection

0: 0 to 10 V
1: –10 to 10 V

Default: 0
Min: 0
Max: 1

No.(Addr.)

Name

Description

Setting

Page

H5-01

(425H)

<14>

<14> If this parameter is set to 0, the drive will be unable to respond to MEMOBUS/Modbus commands.

Drive Node Address

Selects drive station node number (address) for MEMOBUS/Modbus terminals R+, R-, S+, S-.
Cycle power for the setting to take effect.

Default: 1

Min: 0
Max: FF

422

H5-02

(426H)

Communication Speed Selection

0: 1200 bps
1: 2400 bps
2: 4800 bps
3: 9600 bps
4: 19200 bps
5: 38400 bps
6: 57600 bps
7: 76800 bps
8: 115200 bps
Cycle power for the setting to take effect.

Default: 3

Min: 0
Max: 8

422

H5-03

(427H)

Communication Parity Selection

0: No parity
1: Even parity
2: Odd parity
Cycle power for the setting to take effect.

Default: 0

Min: 0
Max: 2

422

H5-04

(428H)

Stopping Method After
Communication Error (CE)

0: Ramp to stop
1: Coast to stop
2: Fast Stop
3: Alarm only

Default: 3

Min: 0
Max: 3

422

H5-05

(429H)

Communication Fault Detection
Selection

0: Disabled
1: Enabled. If communication is lost for more than two seconds, a CE fault will occur.

Default: 1

Min: 0
Max: 1

423

H5-06

(42AH)

Drive Transmit Wait Time

Sets the wait time between receiving and sending data.

Default: 5 ms

Min: 5 ms
Max: 65 ms

423

H5-07

(42BH)

RTS Control Selection

0: Disabled. RTS is always on.
1: Enabled. RTS turns on only when sending.

Default: 1

Min: 0
Max: 1

423

H5-09

(435H)

Communication Fault Detection
Time

Sets the time required to detect a communications error. Adjustment may be needed when
networking several drives.

Default: 2.0 s

Min: 0.0 s
Max: 10.0 s

423

H5-10

(436H)

Unit Selection for MEMOBUS/
Modbus Register 0025H

0: 0.1 V units
1: 1 V units

Default: 0

Min: 0
Max: 1

424

H5-11

(43CH)

Communications ENTER Function
Selection

0: Drive requires an Enter command before accepting any changes to parameter settings.
1: Parameter changes are activated immediately without the Enter command.

Default: 0

Min: 0
Max: 1

424

No.(Addr.)

Name

Description

Setting

Page

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

All Modes

common

_

Advertising