5.8 L: Protection Functions

220

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

L4-03, L4-04: Speed Agreement Detection Level and Detection Width (+/-)

Parameter L4-03 sets the detection level for the digital output functions “Speed agree 2,” “User-set speed agree 2,”
“Speed detection 3,” and “Speed detection 4.”

Parameter L4-04 sets the hysteresis level for these functions.

Refer to H2-01 to H2-05: Terminals M1-M2, M3-M4, M5-M6, P1-PC, and P1-P2 Function Selection on page 197

for

details on settings 13, 14, 15, and 16

L4-05: Speed Reference Loss Detection Selection

The drive can detect a loss of an analog speed reference from input A1 and A2. Speed reference loss is detected when the
speed reference falls below 10% of the previous reference, or below 5% of the maximum output frequency within 400 ms.

Figure 5.37

Figure 5.37 Loss of Reference Function

Parameter L4-05 selects the operation when a speed reference loss is detected.

Setting 0: Stop

Drive follows the speed reference (which is no longer present) and simply stops the motor.

Setting 1: Continue operation with reduced speed reference

The drive will continue the operation at the speed reference value set in parameter L4-06. When the external speed
reference value is restored, the operation is continued with the external speed reference.

L4-06: Speed Reference at Reference Loss

Sets the speed reference level the drive runs with when L4-05 = 1 and a reference loss was detected. The value is set as a
percentage of the speed reference before the loss was detected.

L4-07: Speed Agree Detection Selection

Determines when speed detection is active using parameters L4-01 through L4-04.

Setting 0: No detection during baseblock
Setting 1: Detection always enabled

No.

Parameter Name

Setting Range

Default

L4-03

Speed Agreement Detection Level (+/-)

-100.0 to 100.0%

0.0%

L4-04

Speed Agreement Detection Width (+/-)

0.0 to 40.0%

4.0%

No.

Parameter Name

Setting Range

Default

L4-05

Speed Reference Loss Detection Selection

0 or 1

0

No.

Parameter Name

Setting Range

Default

L4-06

Speed Reference at Reference Loss

0.0 to 100.0%

80.0%

No.

Parameter Name

Setting Range

Default

L4-07

Speed Agree Detection Selection

0, 1

0

100%

400 ms

Analog

speed

reference

10%

common_TMo