5.1 A: Initialization

The initialization group contains parameters associated with initial setup of the drive. Parameters involving the display
language, access levels, initialization, and password are located in this group.

A1: Initialization

A1-00: Language Selection

Selects the display language for the digital operator.

Note: This parameter is not reset when the drive is initialized using parameter A1-03.

Setting 0: English
Setting 1: Japanese
Setting 2: German
Setting 3: French
Setting 4: Italian
Setting 5: Spanish
Setting 6: Portuguese
Setting 7: Chinese
Setting 8: Czech
Setting 9: Russian
Setting 10: Turkish
Setting 11: Polish
Setting 12: Greek

A1-01: Access Level Selection

Allows or restricts access to drive parameters.

Setting 0: Operation only

Access is restricted to parameters A1-01, A1-04, and all U monitor parameters.

Setting 1: User Parameters

Access to only a specific list of parameters set to A2-01 through A2-32. These User Parameters can be accessed using the
Setup Mode of the digital operator.

Setting 2: Advanced Access Level (A) and Setup Access Level (S)

All parameters can be viewed and edited.

Notes on Parameter Access

• If the drive parameters are password protected by A1-04 and A1-05, parameters A1-00 through A1-03, A1-06, and all

A2 parameters cannot be modified.

• If parameters are changed via serial communication, it will not be possible to edit or change parameter settings with the

digital operator until an Enter command is issued to the drive from the serial communication.

No.

<1> Language Settings 8 to 12 can only be selected from an LCD operator with software version 0102 or later. The version number of the LCD

operator PRG software is shown on the back of the LCD operator.

Parameter Name

Setting Range

Default

A1-00

Language Selection

0 to 12

<1>

0

No.

Parameter Name

Setting Range

Default

A1-01

Access Level Selection

0 to 2

2