Verifying parameter changes: verify menu, Refer to verifying parameter, 3 the drive and programming modes – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 98

Advertising
background image

4.3 The Drive and Programming Modes

98

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

Verifying Parameter Changes: Verify Menu

The Verify Menu lists edited parameters from the Programming Mode or as a result of Auto-Tuning. The Verify Menu
helps determine which settings have been changed, and is particularly useful when replacing a drive. If no settings have
been changed, the Verify Menu will read “None”. The Verify Menu also allows users to quickly access and re-edit any
parameter settings that have been changed.

Note: The Verify Menu will not display parameters from the A1 group (except for A1-02, Control Method Selection) even if those

parameters have been changed from their default settings.

The following example is a continuation of the steps above. Here, parameter C1-02 is accessed using the Verify Menu,
and is changed again from 1.50 s to 2.50 s.

The steps below are an example of how to check the list of edited parameters:

12.

Press

as many times as necessary to return to the initial display.

Step

Display/Result

1.

Turn on the power to the drive. The initial display appears.

2.

Press

or

until the display shows the top of the Verify Menu.

3.

Press

to enter the list of parameters that have been edited from their original default settings.

If parameters other than C1-02 have been changed, use

or

to scroll until C1-02 appears.

4.

Press

to access the setting value. Left digit flashes.

Step

Display/Result

- MODE -

U1-01= 0.00%

U1-02= 0.00%
U1-03= 0.00A

DRV

Speed Ref (OPR)

Rdy

RSEQ
LREF

FWD

- MODE -

U1-01= 0.00%

U1-02= 0.00%
U1-03= 0.00A

DRV

Speed Ref (OPR)

Rdy

RSEQ
LREF

FWD

- MODE -

PRG

Modified Consts

HELP

DATA

FWD

Modified

X Parameters

C1-02

= 2.50sec

(0.0~600.00)

“1.50sec”

FWD

- VERIFY -

PRG

Decel Ramp 1

Rdy

Home

DATA

FWD

C1-01=

0

02.50sec

(0.0~600.00)

“1.50sec”

- VERIFY - PRG

Decel Ramp 1

Rdy

Home

DATA

Advertising