5.4 d: Reference Settings

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

177

P

a

ra

me

te

r De

ta

ils

5

d6: Field Forcing

Field Forcing

The Field Forcing function compensates the delaying influence of the motor time constant when changing the excitation
current reference. Field Forcing can improve the motor responsiveness. It is ineffective during DC Injection Braking.

d6-03: Field Forcing Selection

Enables or disables the Field Forcing function.

Setting 0: Disabled
Setting 1: Enabled

d6-06: Field Forcing Limit

Sets the maximum level at which the Field Forcing function can boost the excitation current reference. The value is set as
a percentage of the motor no load current. This parameter does not normally need to be changed.

No.

Parameter Name

Setting Range

Default

d6-03

Field Forcing Selection

0 or 1

0

No.

Parameter Name

Setting Range

Default

d6-06

Field Forcing Limit

100 to 400%

400%