C.4 MEMOBUS/Modbus Setup Parameters

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

423

MEMOBUS

/Mo

dbu

s

C

o

m

m

u

ni

ca

ti

on

s

C

H5-05: Communication Fault Detection Selection

Enables or disabled the communication error (CE) detection for MEMOBUS/Modbus communications.

Setting 0: Disabled

No communication error detection. The drive continues operation.

Setting 1: Enabled

If the drive does not receive data from the master for longer than the time set to H5-09, then a CE fault will be triggered
and the drive will operate as determined by parameter H5-04.

H5-06: Drive Transmit Wait Time

Sets the time the drive waits after receiving data from a master before responding.

Figure C.6

Figure C.6 Drive Transmit Wait Time Setting

H5-07: RTS Control Selection

Enables or disables RTS control.

Setting 0: Disabled. RTS is always on.

Use this setting when using RS-485 signals for communications or when using RS-422 signals for point-to-point
communications.

Setting 1: Enabled. RTS switches while sending.

Use this setting when using RS-422 signals for multi-drop communications.

H5-09: Communication Fault Detection Time

Sets the time the communications must be lost before the drive triggers a CE fault.

No.

Parameter Name

Setting Range

Default

H5-05

Communication Fault Detection Selection

0 or 1

1

No.

Parameter Name

Setting Range

Default

H5-06

Drive Transmit Wait Time

5 to 65 ms

5 ms

No.

Parameter Name

Setting Range

Default

H5-07

RTS Control Selection

0 or 1

1

No.

Parameter Name

Setting Range

Default

H5-09

Communication Fault Detection Time

0.0 to 10.0 s

2.0 s

Command message

Response message

Command message

PLC→Drive

PLC→Drive

Drive→PLC

Time

24 bit length

H5-06 setting

common_

TMonly