O4-09: igbt maintenance setting, O4-12: kwh monitor initialization, O4-13: number of travels counter reset – Yaskawa L1000E AC Drive Technical Manual for CIMR-LE Models for Elevator Applications User Manual

Page 246: 10 o: operator related settings, The kwh data are kept, Keeps the number of travels counter

Advertising
background image

5.10 o: Operator Related Settings

246

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

o4-09: IGBT Maintenance Setting

Sets the value of the IGBT maintenance time displayed in U4-07 as a percentage of the total expected performance life.
Reset this value to 0 after replacing the IGBTs.

Note: The actual maintenance time will depend on the environment where the drive is used.

o4-11: U2, U3 Initialization

Resets the fault trace and fault history monitors (U2-†† and U3-††). Initializing the drive does not reset these
monitors.

Setting 0: No action

The drive keeps the record already saved concerning fault trace and fault history.

Setting 1: Reset fault data

Resets the data for the U2-†† and U3-†† monitors. Once o4-11 is set to 1 and the ENTER key is pressed, fault data is
erased and the display returns to 0.

o4-12: kWh Monitor Initialization

Resets the kWh monitors U4-10 and U4-11. Initializing the drive or cycling the power does not reset these monitors.

Setting 0: No Action

The kWh data are kept.

Setting 1: Reset kWh Data

Resets the kWh counter. The monitors U4-10 and U4-11 will display “0” after they are initialized. Once o4-12 is set to 1
and the ENTER key is pressed, kWh data is erased and the display returns to 0.

o4-13: Number of Travels Counter Reset

The number of travels counter displayed in U4-24/25 is not reset when the power is cycled or the drive is initialized. Use
o4-13 to reset U4-24/25.

Setting 0: No Action

Keeps the number of travels counter.

Setting 1: Resets the Number of Travels

Resets the number of travels counter. The monitor U4-24/25 will show 0. Once o4-13 is set to 1 and the ENTER key is
pressed, the counter value is erased and the display returns to 0.

No.

Parameter Name

Setting Range

Default

o4-09

IGBT Maintenance Setting

0 to 150%

0%

No.

Parameter Name

Setting Range

Default

o4-11

U2, U3 Initialization

0 or 1

0

No.

Parameter Name

Setting Range

Default

o4-12

kWh Monitor Initialization

0 or 1

0

No.

Parameter Name

Setting Range

Default

o4-13

Number of Travels Counter Reset

0 or 1

0