5.10 o: Operator Related Settings

242

YASKAWA ELECTRIC SIEP YAIL1E 01A YASKAWA AC Drive L1000E Technical Manual

o1-23: HBB Non Display Select

Sets the gear ratio of the mechanical gear.

Setting 0: Show HBB
Setting 1: Hide HBB

HBB is not displayed on the digital operator while the safety signal is being input.

o2: Digital Operator Keypad Functions

These parameters determine the functions assigned to the operator keys.

o2-01: LO/RE (LOCAL/REMOTE) Key Function Selection

Parameter o2-01 determines whether the LO/RE key on the digital operator will be enabled or not for switching between
LOCAL and REMOTE.

Setting 0: Disabled

The LO/RE key is disabled.

Setting 1: Enabled

The LO/RE switches between LOCAL and REMOTE operation. Switching is possible during stop only. When LOCAL is
selected, the LED indicator on the LO/RE key will light up.

o2-02: STOP Key Function Selection

Determines if the STOP key on the digital operator can still be used to stop drive operation when the drive is being
controlled from a remote source (i.e., not from digital operator).

Setting 0: Disabled
Setting 1: Enabled

The STOP key will terminate drive operation even if the Up/Down command source is not assigned to the digital
operator. Cycle the Up/Down command to restart the drive if the drive has been stopped by pressing the STOP key.

No.

Parameter Name

Setting Range

Default

o1-23

HBB Non Display Select

0, 1

0

No.

Parameter Name

Setting Range

Default

o2-01

LO/RE Key Function Selection

0 or 1

0

No.

Parameter Name

Setting Range

Default

o2-02

STOP Key Function Selection

0 or 1

0